3-8
3
FRUs and compatibility matrixes
CAUTION:
•
Select fan trays and power supplies with airflow directions that meet the ventilation requirements
at the installation site. As a best practice, make sure the power supplies and fan trays have the
same airflow direction.
•
Do not install fan trays of different models on the same switch. To guarantee adequate heat
dissipation, install five fan trays of the same model on the switch.
•
Do not install power supplies of different models on the same switch. As a best practice, install
two power supplies of the same model on the switch for 1+1 power supply redundancy.
Table3-1 Compatibility matrix between the FRUs and S6805 switches
FRUs
Part No.
S6805-54HF
S6805-54HT
Power supplies
PSR250-12A
0231A6M0
Yes
No
PSR250-12A1
0231A8FP
Yes
No
PSR450-12A
0231A6N9
Yes
Yes
PSR450-12A1
0231A6NC
Yes
Yes
PSR450-12AHD
0231A6NA
Yes
Yes
PSR450-12D
0231A6NB
Yes
Yes
Fan trays
LSPM1FANSA
0231A2VT
Yes in Release 6616 and later Release versions. For
the support of ESS and Feature versions, contact H3C
Support.
LSPM1FANSB
0231A2VU
Yes in Release 6616 and later Release versions. For
the support of ESS and Feature versions, contact H3C
Support.
LSPM1FANSA-SN
(support electronic label
information reading)
0231AG9E
Yes
LSPM1FANSB-SN
(support electronic label
information reading)
0231AG9F
Yes
Power supplies
CAUTION:
When the switch has two power supplies in 1+1 redundancy, you can replace one of them without
powering off the switch. To avoid device damage and body injury, make sure the power supply to be
replaced is powered off before you replace it.