background image

3

Black 120V-277V

White- Neutral

Green- Ground

Rear Panel

Housing

Figure 3

(Note 2)

(Note 1)

(Note 2)

}

LED Array

LED Array

(See above)

1. For wall mount, secure backplate to junction box (screws provided with junction box), and feed input source
wires through center hole in rear panel.  Note: this unit has a wide input range, 120V-277V, eliminating the
need for special wiring based on the input voltage.

2. Connect input power leads (120V-277V) to black lead from unit; neutral to white lead and ground to green
lead.  Once all connections have been made, feed all wires and wire nuts through the center knockout of the
rear panel into the junction box.

NOTE: For wall switch functionality, refer to Section 5 for wiring details.

3. For conduit mounting, remove NPT ½" (refer to Figure 3A), feed input source wires through the conduit and
opening in rear panel into the unit.  Secure the conduit to the rear panel then connect input power leads per
step 2 above.

For conduit mounting (Note 3):

Step 2: Remove NPT ½" Pipe
Plug from top of unit to allow
for conduit installation with
input source wires.

Step 1: Remove Screw and washer
from inside of the rear panel.

Figure 3A

SECTION 3: LUMINAIRE WITH AC ONLY OPERATION WIRING INSTRUCTION

Summary of Contents for WW Series

Page 1: ...ch hot surfaces 4 Equipment should be mounted in locations and at heights where it will not be readily subject to tampering by unauthorized personnel 5 The use of accessory equipment not recommended by the manufacturer Use of such equipment may cause unsafe conditions and will void the unit s warranty 6 DO NOT use this equipment for other than it s intended purpose 7 All servicing should be perfor...

Page 2: ...attery backup will turn ON LED array at the loss of AC power power failure SECTION 2 LUMINAIRE ON OFF CONTROL FUNCTIONS Open enclosure using flat blade screw driver to access knockouts Figure 1A Prior to removing knockouts support rear panel on a base to prevent panel deflection and or damage to the cover s flatness Figure 1 Photosensor Test switch Status Indicator EM Models Only Housing Front Cov...

Page 3: ...d Once all connections have been made feed all wires and wire nuts through the center knockout of the rear panel into the junction box NOTE For wall switch functionality refer to Section 5 for wiring details 3 For conduit mounting remove NPT refer to Figure 3A feed input source wires through the conduit and opening in rear panel into the unit Secure the conduit to the rear panel then connect input...

Page 4: ...on LED driver module 4 Make correct heat pad connection if unit has heat pad option See Section 9 5 Turn on AC source power and press test button proper function is indicated if LED array turns on 6 For conduit mounting remove NPT refer to Figure 3A feed input source wires through the conduit and opening in rear panel into the unit Secure the conduit to the rear panel then connect input power lead...

Page 5: ...Ground green Jumper White Neutral White Hot wire 120 277V Black White Black Orange Figure 7 Input Terminal Block Output to LED Driver Back Plate Grounding Ground green Neutral White Un switched Hot wire Black 120V 277V White Black Orange Figure 8 W S ALL WITCH Switched Hot wire Set slide switch to left position see figure 6 remove jumper from terminal block and connect wall switch to Terminals 1 a...

Page 6: ... wire from heat pad using a wire nut and cap unused black wire from heat pad with wire nut Refer to Figure 9A below If unit heat pad option for cold weather INSTALLER MUST VERIFY AC INPUT SOURCE VOLTAGE TO DETERMINE APPROPRIATE WIRING PRIOR TO TURNING THE FIXTURE ON Refer to the instructions below for voltage dependent instructions WARNING DAMAGE MAY OCCUR IF HEAT PAD IS WIRED INCORRECTLY FOR 277V...

Page 7: ...on the 12th month of each year after fixture has been installed SECTION 11 TESTING AND TROUBLE SHOOTING To manually test battery backup EM units use test switch to simulate AC power outage The LED array will turn on and LED indicator will turn off Release the switch to automatically restore AC Battery charge mode Units with Self Diagnostics Self test capabilities will automatically perform a self ...