IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be
followed including the following:

SAVE THESE INSTRUCTIONS

CONSERVER LA FICHE D’INSTRUCTION

1. Disconnect power at fuse or circuit breaker panel before installing or servicing

of the unit.

2. DO NOT mount in hazardous locations, near gas or electric heaters.
3. DO NOT let power cords touch hot surfaces.
4. Equipment should be mounted in locations and at heights where it will not be

readily subject to tampering by unauthorized personnel.

5. The use of accessory equipment not recommended by the manufacturer.

Use of such equipment may cause unsafe conditions, and will void the unit’s
warranty.

6. DO NOT use this equipment for other than it’s intended purpose.
7. All servicing should be performed by a qualified personnel only.
8. Allow battery to charge for 24 hours before first use.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS:

H3 GROUP

WET LOCATION LUMINAIRE AND

EMERGENCY LIGHT WITH PHOTOSENSOR

SERIES: WW - OWL - ODELL

Summary of Contents for WW Series

Page 1: ...ch hot surfaces 4 Equipment should be mounted in locations and at heights where it will not be readily subject to tampering by unauthorized personnel 5 The use of accessory equipment not recommended by the manufacturer Use of such equipment may cause unsafe conditions and will void the unit s warranty 6 DO NOT use this equipment for other than it s intended purpose 7 All servicing should be perfor...

Page 2: ...attery backup will turn ON LED array at the loss of AC power power failure SECTION 2 LUMINAIRE ON OFF CONTROL FUNCTIONS Open enclosure using flat blade screw driver to access knockouts Figure 1A Prior to removing knockouts support rear panel on a base to prevent panel deflection and or damage to the cover s flatness Figure 1 Photosensor Test switch Status Indicator EM Models Only Housing Front Cov...

Page 3: ...d Once all connections have been made feed all wires and wire nuts through the center knockout of the rear panel into the junction box NOTE For wall switch functionality refer to Section 5 for wiring details 3 For conduit mounting remove NPT refer to Figure 3A feed input source wires through the conduit and opening in rear panel into the unit Secure the conduit to the rear panel then connect input...

Page 4: ...on LED driver module 4 Make correct heat pad connection if unit has heat pad option See Section 9 5 Turn on AC source power and press test button proper function is indicated if LED array turns on 6 For conduit mounting remove NPT refer to Figure 3A feed input source wires through the conduit and opening in rear panel into the unit Secure the conduit to the rear panel then connect input power lead...

Page 5: ...Ground green Jumper White Neutral White Hot wire 120 277V Black White Black Orange Figure 7 Input Terminal Block Output to LED Driver Back Plate Grounding Ground green Neutral White Un switched Hot wire Black 120V 277V White Black Orange Figure 8 W S ALL WITCH Switched Hot wire Set slide switch to left position see figure 6 remove jumper from terminal block and connect wall switch to Terminals 1 a...

Page 6: ... wire from heat pad using a wire nut and cap unused black wire from heat pad with wire nut Refer to Figure 9A below If unit heat pad option for cold weather INSTALLER MUST VERIFY AC INPUT SOURCE VOLTAGE TO DETERMINE APPROPRIATE WIRING PRIOR TO TURNING THE FIXTURE ON Refer to the instructions below for voltage dependent instructions WARNING DAMAGE MAY OCCUR IF HEAT PAD IS WIRED INCORRECTLY FOR 277V...

Page 7: ...on the 12th month of each year after fixture has been installed SECTION 11 TESTING AND TROUBLE SHOOTING To manually test battery backup EM units use test switch to simulate AC power outage The LED array will turn on and LED indicator will turn off Release the switch to automatically restore AC Battery charge mode Units with Self Diagnostics Self test capabilities will automatically perform a self ...