OPERATING CONDITIONS & REQUIREMENTS
Page 4
OPERATING PRESSURE MIN-MAX: 1,4-5,0 bar / 20-73 psi
for cold water applications (max. 48 °C (120 °F)) max. operating
pressure is 8,3 bar (120 psi).
this appliance is configured to perform optimally at an
operating pressure of 3 bar (45 psi) ±½ bar (7 psi); in case of a
lower or higher operating pressure the performance may be
affected negatively!
check water pressure regularly.
take into account that night time water pressure may be
considerably higher than day time water pressure.
install a pressure reducer ahead of the appliance if necessary.
OPERATING TEMPERATURE MIN-MAX: 2-65 °C / 35-149 °F
do not install the appliance in an environment where high
ambient temperatures (e.g. unvented boiler house) or freezing
temperatures can occur.
the appliance cannot be exposed to outdoor elements, such as
direct sunlight or atmospheric precipitation.
ELECTRICAL CONNECTION:
the appliance only works on 24 VAC; always use it in
combination with the supplied transformer.
make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over-
current protection.