exceed approx. 50 °C. If by accident the battery is poled incorrectly then being connected to the
charger, this will be signaled by a red LED “reverse poled” and the charge current will be switched
off automatically.
Note
• When charging batteries it is necessary to ensure that the connection of the batteries are correctly
poled.
• Never deep charge the batteries to avoid damage of the batteries.
• During the charging process ensure that the room is sufficiently ventilated.
• Open the cell plug of the lead-acid batteries (if available).
• Check the acid level of the lead-acid battery before charging.
• Check the acid level from time to time when charging for a longer period of time.
• Avoid open fire, open light and sparks near the charging batteries (danger of explosion through
oxyhydrogen gas).
• It is necessary to consider .the charging instructions of the respective battery manufacturers
(mostly printed on the battery).
l
Specifications
Charging end voltage: 2,3 Volt/6,9 Volt/13,8 Volt
Max. charge current: 0,6 Ampere
Operating voltage: 230 Volt / 50 Hz
Measurements: 90 x 56 x 60 mm
If it is to be assumed that an operation free of risks is no longer possible, the evice must be switched
off immediately and it must be ensured that it cannot be switched on accidentally.
This applies:
• if the device shows visible damages
• if the device is no longer operational
• if components of the device are loose or disconnected.
• if the connecting cables show visible damages.
If the device needs repair,
If the device needs repair, only original accessories may be used.
The use of different accessories can cause damage to person and property.
A repair of the device may only be carried out by a tradesman.
We issue a 2-years guarantee. The guarantee includes free defect elimination that can be linked to
defective material or fabrication defects, further claims are excluded.
We do not assume neither warranty nor liability for damages or secondary damage in relation to this