ELECTRO FREEZE Shake Model CS704
185260
42
13 Troubleshooting Charts
— continued
Keep your freezer in excellent condition. Always contact your Electro Freeze distributor
for replacement parts and maintenance scheduling.
NOTE: Contact your authorized Electro Freeze distributor for instructions prior to
warranty compressor replacement.
QUALITY PARTS
PROTECT
YOUR
EQUIPMENT
PROBLEM
PROBABLE CAUSE
REMEDY
Product dispenses slowly out of
dispensing head.
1.
No product in hopper.
1. Fill hopper.
2.
Product too cold.
2. See “Dispensed product too
hard.”
3.
Mix feed tube not open.
3. Check mix feed tube setting.
Compressor and beater motor
operates only when dispensing.
1.
Defective torque control.
1. Contact your Electro Freeze
Distributor for service.
Compressor will not start -
hums intermittently (cycling on
overload)
1.
Improperly wired.
1. Contact your Electro Freeze
Distributor for service.
2.
Low line voltage.
2. Ask power company to
increase voltage to not less
than 10% below dataplate
rating or have transformer
installed. Have wire checked
for inadequate wire size.
3.
Open start capacitor. (Single
phase only)
3. Contact your Electro Freeze
Distributor for service.
4.
Defective compressor
4. Contact your Electro Freeze
Distributor for service.
Summary of Contents for Arby's Electro Freeze Compact Series
Page 2: ......
Page 7: ...ELECTRO FREEZE Shake Model CS704 Safety Decal Locations v 1 P N HC165126 2 P N HC165025...
Page 10: ......
Page 30: ...ELECTRO FREEZE Shake Model CS704 185260 20 Figure 7 4 Head Assembly 7 Assembly continued...
Page 53: ......
Page 55: ......
Page 65: ...ELECTRO FREEZE Shake Model CS704 185260 10 Figure 8 Panel View Sheet 1 of 2...
Page 67: ...ELECTRO FREEZE Shake Model CS704 185260 12 Figure 9 Side View Sheet 1 of 2...
Page 71: ...ELECTRO FREEZE Shake Model CS704 185260 16 ELECTRO FREEZE Shake Model CS704 16...