GYS CA170 Manual Download Page 5

 

 

 Sulphated batteries 

These  batteries  left  without  servicing  for  too  long  may,  sometime,  partially  recharged  on  “Manual”  mode.  This 
type of battery can be recognised, when under charge, the ammeter remains around 0. 
In this case, put the selector on the fastest charging current and monitor the charger until you see the ammeter 
needle raises from 0. Then, start an automatic charging process. In case it stays on 0 after 5 hours, the battery is 
out of order. 

 

IV - ADVISES AND WARNINGS 

 
• Your charger must be connected to earth. Otherwise, serious danger of electrical chock!

 

• At the end of the charging process you may have emission of explosive gas by the battery (boiling). Avoid any 
spark or flame in the area. 
• Do not attempt to charge non rechargeable batteries. 
• In case of wear or damage to the mains cable, please return the charger to your dealer for repair. 
• Your charger complies with the EMC Directive (decree 92-587) and can be used in domestic premises. The user 
remains liable to recognize the environment and avoid any use close to sensitive apparatus. 

 
 

V - DECLARATION OF COMPLIANCE 
 

GYS certifies that the product described on this manual is manufactured in compliance with the requirements 
of the following European directives: 
- Low Voltage Directive: 2006/95/EC - 12/12/2006 (amended by 93/68/EEC) 
- EMC Directive: 2004/108/EC, 15/12/2004 (amended by 92/31/EEC, 93/68/EEC, 91/263/EEC, 93/97/EEC), 
It therefore complies with the following harmonized standards: EN60335-1 - EN60335-2-29 – EN55014-1 - 
EN55014-2 – EN61000-3-2– EN61000-3-3 – EN62233.

Summary of Contents for CA170

Page 1: ...1 73339 V3 03 12 12 P 2 3 14 16 P 4 5 14 16 P 6 7 14 16 P 8 9 14 16 P 10 11 14 16 P 12 13 14 16...

Page 2: ...placez le commutateur sur la tension d sir e 6 12 ou 24 V 6 Relier les pinces rouge et noir aux bornes et de la batterie en assurant un bon contact 7 Mettre l interrupteur lumineux vert sur ON r gler...

Page 3: ...ue le chargeur d crit dans ce manuel est fabriqu conform ment aux exigences des directives europ ennes suivantes Directive basse tension 2006 95 EC 12 12 2006 amend e par 93 68 EEC Directive CEM 2004...

Page 4: ...capacity number used in the charger s name 5 For the multi voltage chargers select 6V 12V or 24V as required 6 Connect the clamps red black to and battery terminals making sure you get a good electri...

Page 5: ...ng Avoid any spark or flame in the area Do not attempt to charge non rechargeable batteries In case of wear or damage to the mains cable please return the charger to your dealer for repair Your charge...

Page 6: ...htet werden 2 Gr ner Ger tschalter auf off Dann Netzstecker in die Steckdose 3 Batterieverschluss abnehmen falls vorhanden und pr fen ob der S uerstand Elektrolyt die richtige H he hat Gegebenenfalls...

Page 7: ...g nicht mehr zu gebrauchen IV RATSCHL GE UND WARNUNGEN Achtung Nur Stecker und Dosen mit Erde einsetzen Sonst besteht die Gefahr des Elektroschlages Bei Ladeende und kochen der Batterie entweicht hoch...

Page 8: ...lito est correcto si no a adir agua destilada Limpiar correctamente los bornes y los terminales de los cables de la bater a 4 Comprobar que la capacidad de la bater a est compatible con su cargador s...

Page 9: ...finitivamente fuera de uso IV CONSEJOS Y ADVERTENCIAS Cuidado su cargador debe ser conectado a una toma de tierra sino peligroso grave de electrocucion A finales de la carga cuidado con el desprendime...

Page 10: ...10 I 2 AUTOMATI MANUAL E AUTOMATIC W2 OK MANUAL II 1 2 OFF 230 3 4 35 110 5 6 12 ou 24 6 7 ON 3 1 15 A 1 10 8 AUTOMATIC MANUAL 9 OFF III...

Page 11: ...11 OK OFF MANUAL 0 5 IV CEM D 92 587 GYS V GYS CA 170 225 350 2006 95 CE 12 12 2006 CEM 2004 108 CE 15 12 2004 EN60335 1 EN60335 2 29 EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 EN62233...

Page 12: ...oevoegen De batterij klems en kabelschoenen correct schoonmaken 4 Nagaan of de batterijcapaciteit met uw lader verenigbaar is de benaming nummer bekijken 5 Voor de multi spanningen laders de schakelaa...

Page 13: ...r nog niet uitgeslagen heeft de batterij definitief buiten gebruik is IV ADVIES EN WAARSCHUWINGEN Opgepast uw lader moet aan een contactdoos met aarde aangesloten zijn Zo niet is er elektrocutie gevaa...

Page 14: ...n Leer las instrucciones antes de utilizar Choisir un local abrit et suffisamment a r ou sp cialement am nag Choose a sheltered room with appropriate airing Nur im gesch tzt und gut bel ften R ume anw...

Page 15: ...ible Zekering 3 Voyant de charge Charge indicator Ladungslicht Indicador de carga LED voor laden 4 Choix de tension de batterie Battery voltage selector Auswahl der Batteriepannung Selector de tensi n...

Page 16: ...16...

Reviews: