10
CA 150 / 360
EN
Translation of the original instructions
Secondary fuse
Gys reference : 054516
Type : ATOF blade - 25A
Littelfuse reference : 287025.PXPV
Gys reference : 054622
Type: BF1 – M5 - 32V 50A
Littelfuse reference : 153.5631.5502
Sulfated battery
Batteries which have been deeply discharged may be charged/recovered. Such batteries may be identified if the
ammeter needle does not (stays at 0) or if the charger stops quickly when in automatic mode.
In this event, set the charger to “Manual” (CA 360), set the charger on the fastest charging speed and monitor it
every hour. If the needle still hasn’t moved after 5 hours, the battery cannot be recovered.
TROUBLESHOOTING
Symptoms
Causes
Remedies
The ON/OFF button does not
switch on when set to ON.
No mains voltage
Check that the power cord is plugged to a 230V
50/60Hz socket. Check the power supply
network.
The machine's anmeter does
not fluctuate .
Power supply problem.
Check your mains power supply.
Clamps in short circuit or polarity
reversal.
Check that the fuses have not melted and that
the circuit breaker is not tripped
The battery that you are trying to
charge is faulty.
Check the terminals' voltage with a voltmeter.
If this voltage jumps instantaneously to 2.5V
per element, the battery may be sulfated or
damaged.
Voltage error (12 -24V)
Chck that the switch is on the right setting (12
or 24V)
Following intensive use, your
device has entered thermal
protection mode.
Wait 1/4h so the device can cool down.
The charger is properly
connected but it does not
charge the battery
Blown fuse
Replace the fuse by a new one.
Bad clamp connections.
Clean the terminals and the clamps. Check the
state of the cables and clamps.
Wrong charge settings
Check that the selected voltage matches the
battery voltage.
Following intensive use, your
device has entered thermal
protection mode.
Wait 1/4h so the device can cool down.
The anmeter's pin goes above
the maximum marking while
the device is set to minimum
intensity.
The battery is deeply discharged.
Keep charging using the minimum setting .
Voltage error (12 -24V)
Chck that the switch is on the right setting (12
or 24V)
Your battery has elements in short
circuit.
Damaged battery Replace the battery.
The fuse blows every time it
is replaced
Polarity reversal
Connect the + clamp to the battery's (+) and
the + clamp to the battery's (-).
Starting the vehicle
Do not perform any starts when the charger is
connected.
Wrong charge settings
Check that the selected voltage matches the
battery voltage.
Current overconsumption on the
battery
Do not draw any of the battery's current during
the charge
The machine is charging a 12V
battery in 24V mode
Set the switch to 12V.
After charging for a whole
day, the end of charge
indicator does not switch on.
The charger is still in manual mode Switch to automatic mode
The battery is damaged
Change the battery.
The machine is charging a 24V
battery in 12V mode
Set the switch to 24V.