BASIC OPERATION
31
B
ASIC OPERATION
This chapter describes how to set various functions.
Basic Power Supply Functions
Description
The PPH-1503 operates as a generic power supply
with the ability to display different current ranges.
The output can be toggled between the front and
rear outputs using the Rear key. When the Rear
key is lit, it indicates that the rear panel output is
active and that the front panel output is off.And
the front and rear panel can
’
t work at the same
time.
Parameter
Description
IntRate
The data sampling period derived
from the number of power line
cycles.
The setting range is:
0.1PLC to 10.00PLC (power line
cycles)
1PLC = 16.7ms(60Hz)/20ms(50Hz).
*PLC stands for power line cycles.