PEL-3000(H) User Manual
60
+CV Mode
Description
+CV mode can be added to CC, CR and CP mode.
The +CV settings apply to all applicable modes.
Operation
1.
Make sure the load is off.
2.
Press
Main
and select to Mode, I Range and
V Range.
3.
Set the +CV voltage level. (You may need to
scroll down to the +CV setting)
Range:
OFF - rated 5%
Display
Mode
CP + CV
I Range
H 8.75A
V Range
L 80V
Function
Dynamic
Configure
0.000
V
0.0000
A
0.00
W
+CV
5.500
Timer2
0.025
Timer1
0.025
LOAD
RS232
01/Oct/2018
V
ms
ms
+CV setting
Note
The +CV settings apply to all the applicable operating
modes.
For example: The +CV settings made in CR mode will
be carried over to the +CV settings in CC and CP
mode.
Note
+CV settings cannot be controlled with external
control. (The external control is not possible only in
+CV settings)
See page 168 for +CV settings with external control
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...