Voltage Monitor
The input voltage, like the load input current can be
externally monitored with the channel control
connectors. The VMON pin of the channel control
connector outputs a voltage of 0~10V to represent
the load input voltage as a percentage (0~100%) of
the rating voltage.
To determine the Voltage Monitor Output
(VMON) , use the following formula;
V
V
Rating
voltage
input
Load
VMON
10
Where “Rating V” is the rating voltage of the load
module.