GDP Series User Manual
18
GDP-050
Bandwidth
DC-50MHz (-3dB)for x200, x500, x1000
DC-25MHz (for attenuation x100)
Attenuation
X100, x200, x500, x1000
Accuracy
± 2%
Voltage Input
Range (DC+AC
peak to peak)
≤
700Vp-p for x100 (
≅
230Vrms)
≤
1400Vp-p for x200 (
≅
460Vrms)
≤
3500Vp-p for x500 (
≅
1140Vrms)
≤
7000Vp-p for x1000 (
≅
2300Vrms)
Permitted Max
Input Voltage
Max differential voltage: 7000 V (DC+AC
peak to peak)
Max voltage between each input terminal
and ground: 6500 Vrms
Input Impedance Differential: 54M
Ω
/1.2pF
Between terminals and ground:
27M
Ω
/2.3pF
Output
≤
±7.0V
Output
Impedance
50
Ω
Rise Time
7ns for x200, x500 and x1000; 14ns for
x100
Rejection Rate on
Common Mode
60Hz: >80dB; 100Hz: >60dB; 1MHz:
>50dB
Power Supply
External 9V DC power supply
Consumption
Max. 35mA (0.4 Watt)
Environmental
Operating
Conditions
Indoor Use only.
Temperature: Reference: +20
˚
C to
+30
˚
C; Use: 0
˚
C to +50
˚
C; Storage: -30
˚
C
to +70
˚
C
Relative Humidity: Reference:
≤
70%;
Use: 10% to 85%: 10% to 90%
Storage: 10% to 90%
Dimensions and
Weight
240mm x 80mm x 30mm: 280g
Electrical Safety to
IEC 1010-1
Dual Insulation
Installation Category III
Degree of Pollution 2
Rated Voltage or Max Line-Earth:
6500Vrms
Summary of Contents for GDP-025 Series