GDM-8261 Quick Start Guide 

4

 

I

NTRODUCTION 

The GDM-8261 quick start guide is intended for users who are not familiar 
with the instrument and need a tutorial for quickly accessing its major 
functions. For further details including parameters, remote control commands, 
the optional scanner module, digital I/O and specifications, please refer to the 
user manual that is supplied on the accompanying CD. 
Power up the instrument according to the “Powering Up” chapter, and then 
pick up the relevant chapter according to your needs. This guide consists of  
the following chapters: 

 

Powering Up 

 

Basic Measurement 

 

Voltage/Current 

 

Resistance 

 

Diode/Continuity/Frequency/Period/Temp 

 

Advanced Measurement 

 

dBm/dB/Max/Min/Relative/Hold/Compare/Math 

 

Dual Measurement 

All manuals and user guides at all-guides.com

Summary of Contents for GDM-8261

Page 1: ...Dual Measurement Multimeter GDM 8261 QUICK START GUIDE GW INSTEK PART NO 82DM 82610M01 ISO 9001 CERTIFIED MANUFACTURER All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...ritten consent of Good Will company The information in this manual was correct at the time of printing However Good Will continues to improve products and reserves the right to change specifications e...

Page 3: ...ents INTRODUCTION 4 Panel Overview 5 POWERING UP 6 BASIC MEASUREMENT 8 Voltage Current 8 Resistance 9 Diode Continuity Frequency Period Temp 10 ADVANCED MEASUREMENT 11 DUAL MEASUREMENT 13 All manuals...

Page 4: ...igital I O and specifications please refer to the user manual that is supplied on the accompanying CD Power up the instrument according to the Powering Up chapter and then pick up the relevant chapter...

Page 5: ...surement Keys Input Hi Terminal Sense Hi Terminal Sense Lo DC AC 1A Terminal Power Switch Main Display DC AC 10A Terminal Input Lo Terminal AMPS Fuse Holder Main Display Output On Off Key Rear Panel o...

Page 6: ...arrow on the fuse cover on the rear panel 100V 120V 220V 240V 3 Fuse selection Ensure the correct fuse is installed for the line voltage selected Fuse Voltage 0 315AT 100VAC 120VAC 0 125AT 220VAC 240V...

Page 7: ...switch Push the main power switch on the front panel to turn the instrument on The display contents appear and you are ready to make measurements Powering up the instrument is completed All manuals an...

Page 8: ...I ACI 1 Connect the test leads Voltage measurement Current measurement 0 10A Current measurement 0 1 2A 2 Press the measurement key Press the measurement keys on the front panel The measurement result...

Page 9: ...2W resistance 4W resistance 2 Press the measurement key Press the measurement keys on the front panel The measurement result will appear on the display 2W resistance 4W resistance x 2 twice S 4W 2W 2...

Page 10: ...ment keys on the front panel For Continuity Period and Temp F press the same key twice The measurement result will appear on the display Diode Continuity x2 twice Frequency Period x2 twice Temp C Temp...

Page 11: ...ow on the front panel The measurement result will appear on the display Item Keys Descriptions dBm SHIFT EXIT Shows 10 log10 1000 Vrdg2 Rref dB SHIFT EXIT Hz P dB Shows dBm dBmref Max Shows the maximu...

Page 12: ...mathematical operations MX B 1 X Percentage and Statistic based on the other measurement results For further details see the Advanced Measurement chapter in the user manual Please see the Advanced Me...

Page 13: ...V DCV ACI DCI 2W 4W Hz P Note 2W 4W measurements in combination with other measurements are possible but may not be practical as the measurement accuracy is not guaranteed 1 Connect the test leads Vol...

Page 14: ...rocedures in the Basic measurement chapter to choose a primary measurement Page 8 3 Choose a secondary measurement Press the 2nd key then the target item example ACV The display updates the measuremen...