Information requirement for electric local space heaters
Model identifier(s): HP109.VG (mod. DQ1016) / HL61830si
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space
heaters only (select one)
Nominal heat
output
Pnom
1.8
kW
manual heat charge control, with
integrated thermostat
No
Minimum heat
output
(indicative)
Pmin
1.0
kW
manual heat charge control with
room and/or outdoor temperature
feedback
No
Maximum
continuous
heat output
Pmax,c
1.8
kW
electronic heat charge control with
room and/or outdoor temperature
feedback
No
Auxiliary
electricity
consumption
---
---
---
fan assisted heat output
No
At nominal
heat output
elmax
N.A
kW
Type of heat output/room temperature
control (select one)
At minimum
heat output
elmin
N.A
kW
single stage heat output and no
room temperature control
No
In standby
mode
elSB
N.A
kW
two or more manual stages, no
room temperature control
No
with mechanic thermostat room
temperature control
Yes
with electronic room temperature
control
No
electronic room temperature control
plus day timer
No
electronic room temperature control
plus week timer
No
Other control options (multiple selections
possible)
room temperature control, with
presence detection
No
room temperature control, with
open window detection
No
with distance control option
No
with adaptive start control
No
with working time limitation
No
with black bulb sensor
No
Contact details
Refer to Applicant Name / Address
GGV Handelsgesellschaft mbH & Co. KG
August-Thyssen-Str. 8, D-41564 Kaarst-Holzbüttgen