AQUASCOPE 3
Version 1.3
17/19
10.
Battery replacement
At the back of the amplifier is the battery compartment. Please lift the
battery compartment cover. There are 4 LR6 (AA) size alkaline
batteries. When the battery charge indicator on the display suggests
replacing the batteries, please make sure that all 4 batteries are
replaced at the same time. When inserting the batteries please observe
the correct direction (+ and – according to the indicated position).
11.
Technical Specifications
1.
The control unit should be manufactured from a high
strength PVC material that is resistant to exposure from
high levels of UV exposure.
2.
Power supply comprises of 4 x standard LR6” or “AA”
Alkaline batteries.
3.
The System has a Frequency range of 1 – 5000Hz
4.
The control unit has amplification of 60DB or more.
5.
The Sensitivity in the hand probe is 15v/g or more.
6.
The Sensitivity in the ground microphone is 20 v/g or more.
7.
The Aquascope 3 has a display showing battery status,
noise level, volume setting and signal strength.
8.
The center frequency of a band-pass filters shown as a
numeric value. The operator tunes into the exact filter
setting required in increments of 40Hz.
9.
Activating the filters only takes one simple button press.
10.
The filter settings have a narrow bandwidth to allow for
optimal acoustic tuning of the leak noise.
11.
The ground microphone to cable connector is at a height
greater than 400mm from the floor so it cannot be
accidentally kicked by the operator.
12.
The ground microphone to controller cable runs within the
ground microphone handle, this reduces exposure to
increased background noise from wind.