background image

6

LIGHTING INSTRUCTIONS

The appliance is equipped with standing pilots; each pilot is located next to each of the burners.  Pilots should be 

lighted immediately after the gas is turned on by the manual shutoff valve.

1.  Turn control knobs to "OFF" position.
2.  Light pilot with a lighted taper. 
3  The pilot valves are located on the manifold installed 

at the front of the unit behind the front panel.  For 

access to the valves

4.  Loosen the set screws securing the knobs in position, 

and remove the knobs.  Remove the front panel, 

which is attached to the frame with 4 sheet metal 

screws. 

5.  Turn the adjustment screws on the front of the pilot 

valves.  The pilots should be adjusted to  blue short 

flame (1/4" high) to have good ignition to the burners. 

Repeat for remaining pilots.

6.  If the pilot(s) is out turn off gas, wait 5 minutes and 

repeat steps (1) through (5).

ADJUSTING BURNERS

7.  With control valve for the front burner turned to 

full "ON" position, close the air shutters to give a 

soft blue flame having luminous tips and open to a 

point where the yellow tips disappear, then tighten 

the locking screws. Repeat this procedure with the 

remaining burners.

8.  Install the front panel to the front of the frame & reconnect and secure the knobs back into position.

  

ADJUSTING UNIT FOR USE ON PROPANE GAS

Units are shipped with orifices and pressure regulator for operation with natural gas (6" water column).  To convert 

unit from natural to propane gas follow these instructions (Note:  LP models are factory set for propane gas and do 

not require a conversion.  These can be converted to natural gas using the natural gas orifices and converting the 

regulator to natural gas):

1.  Set regulator outlet pressure to 10" water column. A 1/8" pipe plug on the manifold can be removed for 

attaching a pressure gauge.   Remove the slotted cover from the pressure regulator and invert the plug. 

Replace the cover on the regulator and plug on the manifold. Regulator is now set at 10" W.C.

2.  Remove natural gas orifices, #46 for all models and install propane orifices, painted black, (#54 for all models) 

located in a bag on the outside of the front panel. In order to remove natural gas orifices:

 

a. Remove grates and burners.

 

b. Remove orifices from the control valves and fittings on extended gas pipes, replace with the propane orifices.

 

c. Install burners and grates.

OPERATING PROCEDURE

Each burner will deliver up to 22,000 BTU/HR of heat on all models except 601SPRD (on 601SPRD each burner 

is rated 55,000 BTU/HR for natural gas and 45,000 BTU/HR for propane) and is controlled by a manual On/Off 

valve. The right control knob controls the front burner and the left control knob controls the rear burner on all models 

except 601SPRD. On the 601SPRD, the right control knob controls the inner burner and the left control knob 

controls the outer burner. After the pilot is once lit and adjusted, the burners will ignite automatically by turning the 

control knob to any position between On and Off.

CLEANING THE EXTERIOR (Stainless Steel Only)

The exterior surface can be kept clean and attractive by regularly wiping it with a clean soft cloth. Any discoloration 

can be removed with a non-abrasive cleaner. The burner grates and trough tray can be removed for cleaning.

MAINTENANCE AND REPAIRS

Contact the factory or one of its representatives or a local service company for service or maintenance if required.

1/4” 

Flame

Pilot Valve

Air Shutter

Control

Valve

Pilot

IL2426

Summary of Contents for AMHP2

Page 1: ...1 GAS HOT PLATE MODEL AMHP2 AMHP4 AMHP6 Installation Operation Parts Manual 2M Z15770 Rev 4 12 12 IL2424 ...

Page 2: ...re not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Please record the model number serial number voltage and purchase date in the...

Page 3: ...s Sizes available in 12 24 or 36 widths to fit almost anywhere and suitable for a variety of pots and pans High performance 22 000 BTU cast iron burners provide maximum heat distribution and control Heavy duty cast iron grates stand up to constant use Standing pilot for each burner for easy ignition Manual on off control valve has 1 4 turn for easy temperature control Cool to the touch stainless s...

Page 4: ...liance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG For your protection we recommend a qualified installing agency install this appliance They should be familiar with gas installations and your local gas require...

Page 5: ...ent entry of dirt Do not remove this seal until the actual connection is made to the gas supply line CHECKING FOR GAS LEAKS Soap and water solution or other material acceptable for the purpose shall be used in locating gas leakage Matches candle flame or other sources of ignition shall not be used for this purpose AIR SUPPLY Provisions for adequate air supply must be furnished AIR INTAKES IN BOTTO...

Page 6: ...converting the regulator to natural gas 1 Set regulator outlet pressure to 10 water column A 1 8 pipe plug on the manifold can be removed for attaching a pressure gauge Remove the slotted cover from the pressure regulator and invert the plug Replace the cover on the regulator and plug on the manifold Regulator is now set at 10 W C 2 Remove natural gas orifices 46 for all models and install propane...

Page 7: ...7 ...

Page 8: ...Model AMHP Gas Hotplate SK2573 Rev 3 13 12 1 2 3 4 5 6 8 9 10 13 14 15 22 16 17 18 19 20 21 11 12 7 ...

Page 9: ... 4 1 2 13 AMHP2 11 I4 Z6024 1 PAN 12 AMHP2 I4 Z6025 PAN 24 AMHP4 I4 Z6026 PAN 36 AMHP6 12 2C 8833 AR SCREW 8 18X1 2 HEX STL NP AMHP2 13 2R W498 2 KNOB RED AMHP2 4 AMHP4 6 AMHP6 14 2M Z15723 1 FRONT GRAPHIC AMHP2 2M Z15724 AMHP4 2M Z15725 AMHP6 15 I4 Z15873 1 FRONT PANEL 12 AMHP2 I4 Z15874 FRONT PANEL 24 AMHP4 I4 Z15875 FRONT PANEL 36 AMHP6 16 2V Y8832 2 VALVE MANUAL GAS AMHP2 4 AMHP4 6 AMHP6 17 2A...