Gurin BPM265W Instruction Manual Download Page 8

27

Warranty Information

The unit is guaranteed to be free of defects in workmanship and materials under 
normal use for a period of TwoYears from the date listed on the purchase record.
For repair under this warranty. Our authorized service agent must be advised of 
the fault within the period of the warranty. This warranty covers parts and labor 
only under normal operations. A transportation fee or freight fee that may be 
incurred will be the owner's responsibility. Any defect resulting from natural 
causes, e.g., flood, hurricane etc., is not within this guarantee. This guaranty 
does not cover damage incurred by: use of the unit not in accordance with the 
instructions, accidental damage, or being tampered with or serviced by 
unauthorized service agents. 
Monitor subjected to misuse, abuse, and neglect of these manual content,
non-instructional purposes; unauthorized repair or modifications will be 
excluded from this warranty. This guarantee specifically excludes expendables 
and consumables, for example batteries. All warranty claims must be directed to 
the distributor responsible for the sale of the device. The content of this 
warranty is subject to change without further notice.
Periodical check:
Sensitive measuring devices must be checked from time to time for accuracy 
and leakage, we therefore recommend that the performance should be checked 
every 2 years
Check and maintenance and repair for the unit, please contact the local 
distributor for details. 

26

Statement

The intended use: The unit is intended to be used by adults at home or medical 
centre to measure blood pressure and pulse rate.

The unit satisfies the requirements of IEC60601-1 Medical electrical equipment, 
EN1060-1: Non-invasive sphygmomanometer, EN1060-3: Non-invasive 
sphygmomanometer.

The unit has passed the EMC Test.

Blood pressure measurements determined with this device are equivalent to 
those obtained by a trained observer using the cuff/stethoscope auscultatory 
method, within the limits prescribed by the American National Standard, 
Manual, electronic, or automated sphygmomanometers.

The risk of patient and user can be lowered to acceptable level.

Substitution of a cuff different from that supplied might result in measurement error.

Please contact us if you need the circuit diagrams, component part lists etc.

Specifications are subject to change without notice due to improvements in 
performance.

Federal law restricts this device to sale by or on the order of a physician.

Summary of Contents for BPM265W

Page 1: ...mportant Safety Notes 2 Important Safety Notes 2 Know Your Unit 3 Know Your Unit 3 Battery Installation Replacement 4 5 Battery Installation Replacement 4 5 Initialization 6 9 Initialization 6 9 Proper Way of Measurement 10 13 Proper Way of Measurement 10 13 Take a Measurement 14 15 Take a Measurement 14 15 Use the Memory Function 16 17 Use the Memory Function 16 17 About Blood Pressure 18 19 Abou...

Page 2: ...use in measuring blood pressure and pulse rate for adult only not recommended for neonatal baby Do not use a cellular phone near the unit It may result in operational failure Please avoid using in high radiant area in order to make your measuring data correctly Do not disassemble or attempt to repair the unit or components Do not use the equipment where flammable gas such as anesthetic gas oxygen ...

Page 3: ...n and so forth Finally pressing the setting button again to confirm year and start to enter the setting of date To set year 6 Initialization To select user Initialization settings include user setting year date time setting and unit setting The unit stores automatically 180 sets measurement values for 2 users 2 90 with the date and time Set all of the parameters well before taking a measurement fo...

Page 4: ...low the BP monitor to support your arm as the figure shown below Keep your wrist at the same level of your heart Sit upright in a chair and take about 10 times deep breath to relax your entire body especially between your elbow and fingers Then turn on the unit and start to measure 4 3 2 1 10 Proper Way of Measurement 1cm Wrap the cuff tightly around your wrist by using the Velcro strip 2 Remove a...

Page 5: ...o calculates an average reading based on the values of the latest 3 times measurement taken The symbol M and the relative times will appear at the same time after you press the memory button How to Use the Memory Function 15 Take a Measurement Please rest for at least 30 seconds before taking the next measurement The unit will automatically turn off after two minutes if you have forgotten to turn ...

Page 6: ...into different categories the higher category should apply WHO Red Yellow Blue 80 85 90 100 110 Diastolic Blood Pressur mmHg 120 130 140 160 180 Systolic Blood Pressure mmHg Optimal blood pressure target value Normal blood pressure Normal systolic value Mild hypertension Moderate hypertension Severe hypertension After each measurement is completed the LCD display will show your position automatica...

Page 7: ...on Cuff Model No Display Measurement Localization Measuring Principle 23 Care and Maintenance naphtha thinner gasoline Remove the batteries if the unit will not be used for 3 months or longer Always replace all of the batteries with new ones at the same time Store the unit in a clean and dry location Do not subject the unit to extreme hot or cold temperature humidity and direct sunlight Do not wet...

Page 8: ...is warranty is subject to change without further notice Periodical check Sensitive measuring devices must be checked from time to time for accuracy and leakage we therefore recommend that the performance should be checked every 2 years Check and maintenance and repair for the unit please contact the local distributor for details 26 Statement The intended use The unit is intended to be used by adul...

Reviews: