Introduction
G&D MultiPower-2-RPM ·
3
English
Introduction
The central power supply
MultiPower-2-RPM
supplies up to two devices with a voltage
of
12 Volt
. The maximum permissible current consumption per device is
800 A
.
Use a power loop cable to connect the Mini-DIN 4 sockets of the two connectable
devices to a Mini-DIN 4 socket of the central power supply.
At least one internal power supply supplies the voltage of the central power supply.
A second, internal power supply ensures uninterrupted operation if one of the two
external power supplies fails.
Scope of delivery
1 × central power supply
MultiPower-2-RPM
2 × power cable (
PowerCable-2 Standard
)
2 × power loop cable
1 × manual
12VDC/800mA
1
2
In
Main
Red.
Out
Out 1
Out 2
Power
Status
Output
Main Power
Red. Power
100-240VAC/60-50Hz/0.5-0.3A
100-240VAC/60-50Hz/0.5-0.3A