background image

operation manual

Five: Anion

Six: UV light, effective 

sterilization

Produce large amounts of negative ions, 
physical adsorption, eliminate odors, has a 
strong adsorption.

Effectively kill a variety of common bacteria 
and viruses, inhibit the production of bacteria 
and viruses.

Cold cathode UV lamp trigger voltage is 

only 500v,will not produce ozone, can use 

it safely.

Tips

The allergens

Bacteria

Coarse dust Hair Harmful Particles

Dander

Dust 

Pollen

Pet fur

Smoke

Yeast

Mycotic spore

Mould 

Bacteria

Virus

Mildew

Dust mites

Odor Chemical substances

Summary of Contents for AP3001

Page 1: ...OPERATION MANUAL TYPE AP3001 Please read this manual carefully and follow this manual strictly Please keep it properly after reading for future reference ...

Page 2: ...CONTENTS operation manual ...

Page 3: ...g air purifier Auto mode Night mode Silent mode 5 Cleaning and Maintenance Clean air purifiers Clean air quality sensors 6 Fault handling Warranty and service 7 Additional information 8 Warranty description 9 Warranty card Recycling To order parts or accessories Accessories Clean pre filter Replace filters Time for replacement of filters Wind speed adjustment Negative ion Ultraviolet Timing functi...

Page 4: ...ause electric shock failure or fire accident Before start the air purifier please insert the plug completely into the socket Failure to fully inserted into the socket may cause electric shock and overheating or fire accident Ban rod or other metals placed in the outlet or inlets Otherwise it may affect the internal parts and cause electric shock or damage Do not use damaged plug or loose power soc...

Page 5: ...acco or mars to float into the machine This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Away from the fire Otherwise it may cause fire accident Chil...

Page 6: ...duction Handle Air outlet Air quality indicator Air inlet two sides UV tube Photoresistance Activated carbon filter Efficiency HEPA filter The front panel Pre filter Photo catalyst filter Back cover Power cord hole Air Quality Sensor ...

Page 7: ...adjustment Timing button Power button Restoration button Air quality indicator Notice Please press the restoration button if you want to turn off the air quality indicator light PM2 5 digital display just for reference Perfect Blue Green Purple Red PM2 5 0 50 PM2 5 50 100 PM2 5 100 150 PM2 5 150 Good Bad Normal ...

Page 8: ...us to achieve the best performance After removing the plastic package of each filter the efficient HEPA filter and activated carbon filter must be replaced once a year Photocatalyst filter should be replaced every three years after a period of time should exposure under sunlight more than 2 hours Air quality indicator can reflect the air quality conditions please refer to the specific page 6 and p...

Page 9: ...he groove at both sides of the front panel then gently pull it up Reinstall the front panel alignment and insert it into the fixed groove and then gently push it up In order to make your room air to achieve good effect on both sides of the cycle to ensure the gap between the air inlet and the wall at least 50 cm the air outlet at least 10 cm Please keep 1 meter away from television radio etc Pleas...

Page 10: ... and put the purifier on the dry stable horizontal ground Please make sure the power plugs have been put off before installation maintenance and transportation You can put the purifier on the wall to enhance the stability when removing or installing the filters Please do not operate the air purifier without the filters Please remove the package of each filter before using 2 Hold on the grooves at ...

Page 11: ... pre filter as the instruction Please be carefully when install the front panel Tips 7 Install the front panel again Align and insert it to the fixed grooves then gently push it 5 Please pull out the transparent tape from UV lights ...

Page 12: ...us particulate matter Blocking rate 99 9 It can be cleaned easily by tens of thousands times Preventing larger particles such as pet fur dander and coarse dust etc Can increase the life of the following filters The rate of removing the minor particles small to 0 3 micron from the airflow can up to 99 9 Spread of allergens and bacteria in air flow such as pollen smog and viruses Use Nano TIO2 as re...

Page 13: ...tively kill a variety of common bacteria and viruses inhibit the production of bacteria and viruses Cold cathode UV lamp trigger voltage is only 500v will not produce ozone can use it safely Tips The allergens Bacteria Coarse dust Hair Harmful Particles Dander Dust Pollen Pet fur Smoke Yeast Mycotic spore Mould Bacteria Virus Mildew Dust mites Odor Chemical substances ...

Page 14: ... then all the lights off leaving only the power indicator light in red enter the standby mode Press the power switch to enter into auto mode with the lights on When auto mode start it will detect the air quality automatically When the machine start the air quality indicator light will be slow flashing on it begins to detect the air quality after preheating for 30s ...

Page 15: ...ill sense the strength of the light if the light intensity is under the condition of insufficient all lights of the machine will be dimmed and at the same time the machine automatically change to silent mode of operation do not disturb your rest at night Night mode can only be used together with the auto mode Air quality indicator Notice Please press the restoration button if you want to turn off ...

Page 16: ...data both for AP3001B Style Reset the machine by pressing the button for at least five seconds This function is only available after the replacement remind of filter when air quality is poor indoor it needs extra strong airflow Choose enhanced wind speed airflow When the enhanced fan speed is activated all the LED light of wind speed will be lighten up ...

Page 17: ...ry cotton swabs 5 Remount the protective cover of air quality sensor Clean air purifier Clean air quality Sensor Attention Clean the medial and lateral regularly to prevent dust accumulation 1 use soft dry cloth to wipe the dust 2 use soft dry cloth to clean inlet and outlet Clean the air quality sensor every two months to make sure purifier run at the best performance If the purifier used in dust...

Page 18: ... the plastic packaging and ensure that the labels on the filters are outwards In order to achieve the best performance clean and maintain the Pre filter every two months about 480 hours from the beginning to use Based on the average 8 hours a day 7 days a week frequency keep the machine working under the household environment External maintenance use wet cloth or the mild detergent to wipe the sur...

Page 19: ... insert into the fixed groove then gently pushed it up 8 Plug in 9 Turn on the power and start the air purifier 6 Put back the pre filter into the air purifier 5 Use a soft brush or a vacuum cleaner to remove particles please use water or soap water to clean the filter then place it into the machine when it is completely dry ...

Page 20: ...g After the indicator light of replacement of filter shows the machine can still work Please turn off the power and pull out the power plug before replacing the filter Remove all the plastic packaging of each filter before put into machine To ensure the filter label is outward 1 Reminding to replace the filter Attention Tips 2 Turn off the power then pull out the power plug 3 Hold on the grooves o...

Page 21: ...gnment and inserted into the fixed groove then gently push it up 8 After replacing the filter plug in power hold on the reset button for 5 seconds then machine resets 6 Put back the pre filter into the purifier 5 Remove all the plastic package of the filters put back into the purifier ...

Page 22: ...t showed when it works But the machine still can work when get the notice of changing the filter 1 Consider you and your family s health please change the filter screen in time 2 After sealing off filter if the usage time is shorten But suggest to change one time per six months 3 After sealing off filters the filter should be changed one time per 12 months 4 Photo catalyst can be changed one time ...

Page 23: ...act with our customer center or dealers To ensure the machine work in the suitable area Before using please remove plastic packaging of each filter To ensure that all the filters put the correct sequence in machine To ensure the machine at least 50 cm clearance on both sides of the air inlet and the outlet at the back of the machine at least 10 cm The motor is loose Washable mesh filter is dirty F...

Page 24: ...please don t put together with the general life garbage Please check the local regulations on classified collection of electronic and electrical products Right place old product helps to avoid the potential negative effects on the environment and human health ...

Page 25: ...il order product spare parts can with your company s customer service mail order also can buy in the local branch 4 If the specifications have a fixed number of years of the warranty commitment subject to our manual Have no free services and repairs if occurred below situation 1 Without three guarantees proves and effective invoice 2 The malfunction is caused from operating machine without follow ...

Page 26: ...9 Warranty Card Product name item No Purchase Date Name Address Mobile Phone Zip Code Maintenance record Shop name Phone number Dealer stamp Fuselage number operation manual ...

Page 27: ......

Page 28: ......

Reviews: