730372.doc 3429 

7

For replacement parts you can call the Guest Co. at 203-235-4421 or contact your local 

dealer.

 

Replacement bulb kit 

 

729494 

Control Panel 

729829-P 

Lower motor 

U-3135 

Relay PC board (503A spotlight Base) 

729978 

Extension Cable Kit 

729528 

Safety glass lens 

 

B-23186

 

Gasket for Control 

729962 

Base mounting gasket for Spotlight 

728372 

Spot/Flood Reflector 

D-23127-1 

Dual Station Kit 

729830-P 

 
 

NOTE: 
THE CONTROL  PANELS USED WITH GUEST MODELS 500A, 501A, OR 502A WILL 

NOT 

OPERATE THE MODEL 503A SPOT/FLOOD LIGHT. 

 

 

Troubleshooting 

 

Under normal use, your Guest Beamer spotlight will provide you with many years of 
reliable service. 

If an operational problem occurs: 

Confirm that all fuses are intact

.  

If a fuse 

has

 blown, do not replace the fuse until the   

cause of the problem has been located and corrected.  NEVER replace a blown fuse with a higher 

value fuse.  

Most problems are caused by poor wiring connections. 

Confirm that all wiring  

connections are accurate

 

and well made. Be sure that the spotlight and control are connected to a  

12 volt DC power source capable of supplying 10 amps even while other equipment is operating.  
(See diagram on page 5.) 

If the spotlight does not move or light

, remove the 4 bolts that fasten the spotlight onto 

the   mounting surface and gently lift the light until you can see inside

 

its base .  Avoid cutting any 

wires.  Gently inspect the base for broken connections. Examine the circuit board for loose plug 
connectors, blackened components or corrosion. Replace the circuit board if it appears damaged. 

If there are no loose wires or signs of water penetration, re-install the spotlight and then replace 

the control pad. If there signs of water damage, return the spotlight and control to the Guest Co. 
Service Department for repair, include information about how and where the spotlight was 

installed. 
 

Summary of Contents for 503A BEAMER

Page 1: ...3A BEAMER REMOTE CONTROL SPOT FLOOD LIGHT INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT KEEP THESE INSTRUCTIONS FOR FUTURE REFERENC...

Page 2: ...signed for 12 volt operation only Tools and additional materials required Electric drill with 1 2 13mm 5 16 8mm and 3 16 5mm bits Wire crimping tool Phillips head screwdriver 2 7 16 11mm wrenches Non...

Page 3: ...wer tools 4 Install the foam gasket on to the base of the spot flood light making sure that all eight wires exit through the center hole in the gasket 5 Feed the eight wires coming out of the base of...

Page 4: ...not to scale make sure that the holes are horizontal to each other 1 5 38mm 3 0 76 5mm 2 Places 3 16 5mm hole hole 1 2 13mm reference 3 26 82 8mm reference 3 9 100 2mm 3 Feed all of the Control Panel...

Page 5: ...rectly to the main 12 volt DC accessory panel Install fuse and fuse holders as shown in diagram A 10 amp circuit breaker can be installed instead of an in line 10 amp fuse If the light will be less th...

Page 6: ...oodlight while it is operating DO NOT cover the light with a fabric cover or any other flammable material Accidental activation may result in a fire hazard DO turn the spotlight toward the control sta...

Page 7: ...R replace a blown fuse with a higher value fuse Most problems are caused by poor wiring connections Confirm that all wiring connections are accurate and well made Be sure that the spotlight and contro...

Page 8: ...rol panel If your light has a problem that is not described above contact the GUEST Co Service Department for assistance LIMITED WARRANTY For one 1 year from the date of original purchase The Guest Co...

Reviews: