2.  INSTALLING THE CHARGER 

 
AC Connection and Grounding Precautions: 

DANGER 

DO  NOT  OPERATE  THIS  CHARGER  WITH  A  TWO  BLADED 
ADAPTER PLUG OR EXTENSION CORD.  DOING SO CAN RESULT 
IN  SERIOUS  PERSONAL  INJURY.    DO  NOT  ATTEMPT  TO  WIRE 
THE BATTERY CHARGER USING AN ELECTRICALLY ENERGIZED 
LINE CORD.  WIRE THE CHARGER ONLY WHILE THE WIRING OR 
AC  SOURCE  IS  DE-ENERGIZED.    AFTER  SECURING  THE 
BATTERY  CONNECTIONS,  PLUG  THE  AC  LINE  CORD  INTO  AN 
AVAILABLE  AC  OUTLET  THAT  IS  PROTECTED  BY  A  GROUND 
FAULT CIRCUIT INTERRUPTER (GFCI) BREAKER.  DO NOT PLUG 
INTO AC UNTIL ALL CHARGER CONNECTIONS ARE MADE. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Making AC Connections: 

 
Reference the above drawing: 
 

1.

 

Make  AC  connections  to  the  charger  by  wiring  AC  Hot  or  Line  to  the  AC  LINE 
terminal, wire AC Neutral to the AC NEUT terminal, wire Earth Ground to the AC 
GND terminal.    

2.

 

To  interface  between  the  conductor  and  the  stud  terminal,  use  either  a  fork  or 
ring terminal appropriately sized for a ¼” stud.  

 

Summary of Contents for 2614A

Page 1: ...12 12 2621A 230 2622A 10 10 Amps 2 Bank 12 12 2622A 230 See Section 3 diagrams for specific connection instructions IMPORTANT NOTICE This manual contains important safety and operating instructions f...

Page 2: ...USE ON OTHER BATTERY TYPES MAY CAUSE AN EXPLOSION OR PERSONAL INJURY RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OF LEAD ACID BATTERIES IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORM...

Page 3: ...forcefully blown away using a piece of cardboard or other non metallic material as a hand fan 5 Clean battery terminals Be careful to keep corrosion from coming in contact with eyes 6 Add distilled w...

Page 4: ...R SECURING THE BATTERY CONNECTIONS PLUG THE AC LINE CORD INTO AN AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER GFCI BREAKER DO NOT PLUG INTO AC UNTIL ALL CHARGER CONNECTI...

Page 5: ...larity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGATIVE NEG N post 2 Connections to the battery should be made with industry standard color coding C...

Page 6: ...APPLICABLE 2621A 15 AMP FUSE 15 AMP FUSE 15 AMP FUSE 2622A 15 AMP FUSE 15 AMP FUSE NOT APPLICABLE Choosing Charging Location The charger should have at least eight inches of unobstructed area on all...

Page 7: ...75 Amp 2614A 230 12 12 5 10 2 YES 230VAC 50 60Hz 2 5 Amp Diagram 1 Standard Connections for a 2614A 5 10 Amps used with 2 independent 12V Batteries 2614A Connection Warnings Do not connect the output...

Page 8: ...ax 2621A 12 12 12 5 5 10 3 YES 115VAC 50 60Hz 5 Amp 2621A 230 12 12 12 5 5 10 3 YES 230VAC 50 60Hz 2 5 Amp Diagram 2 Standard Connections for a 2621A 5 5 10 Amps used with 3 independent 12V Batteries...

Page 9: ...t connect output 3 10 amp of the 2621A in series or in parallel with output 1 or output 2 while charger is AC powered ON Charge separate batteries only While charger is AC powered on battery switch mu...

Page 10: ...Amps Max 2622A 12 12 10 10 2 YES 115VAC 50 60Hz 5 Amp 2622A 230 12 12 10 10 2 YES 230VAC 50 60Hz 2 5 Amp Diagram 4 Standard Connections for a 2622A 10 10 Amps used with 2 independent 12V Batteries 26...

Page 11: ...tery By doing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both lights stay on longer than 24 hours refer to Problem 2 in the troubles...

Page 12: ...oing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both lights stay on longer than 24 hours refer to Problem 2 in the troubleshooting s...

Page 13: ...Ready State 2 One or more defective or damaged cells 3 Extremely low AC voltage at the battery charger 1 Turn off all DC equipment while charging 2 Load test the batteries and replace if necessary 3...

Page 14: ...del Output Volts Output Amps Banks Output Circuit Breakers Input Volts Input Amps Max 2614A 12 12 5 10 2 YES 115VAC 50 60Hz 3 75 Amp 2614A 230 12 12 5 10 2 YES 230VAC 50 60Hz 2 5 Amp 2621A 12 12 12 5...

Page 15: ...correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an ou...

Reviews: