If the in-line 6 amp fuse blows due to improper connection to a battery, replace the 
fuse with an identical 6-amp fast-blow fuse only. Never replace a blown fuse with a 
higher value fuse. 

The 2603 is completely waterproof, however the AC plug and DC clip-on connections 
should be kept dry.

 

5. MAINTAINING THE CHARGER 

 

Periodically clean both battery terminals with baking soda and tighten all   connections.  
No other maintenance on the charger is required. 

 

6. TROUBLESHOOTING

 

Problem 

Cause 

Solution 

1.

 

Charger does not seem 
to be charging batteries 
properly. 

1.

 

Batteries too large for the 
charger to support or too 
many batteries attached 
to charger. 

2.

 

Red LED is off due to a 
DC overload or a DC 
short. 

3.

 

One or more defective 
batteries. 

4.

 

Component failure. 

 

1.

 

Install a higher 
Amperage battery    

         Charger or a second 
         Charger. 

2.

 

Remove source of 
overload or short and 
perform the reset 
procedure as described 
under “Operation”. 

3.

 

Test batteries and replace 
if necessary. 

4.

 

Check battery 
manufacturer’s charging 
specifications. 

5.

 

Return charger to Guest 
Service department. 

2.  Static on TV or radio 

whenever the charger is 
turned on. 

1.

 

Certain TV’s and 
Radios are  

         Unusually sensitive   
          To RF interference. 
2.

 

Charger is mounted 
within 3 feet of TV or 
radio. 

1.

 

Increase the distance 
between the charger and 
the TV or radio. 

2.

 

Connect TV or radio to an 
AC circuit other than the 
AC circuit used by the 
charger. 

Summary of Contents for 2603 Battery Pal

Page 1: ...xtend your battery s life in applications where it is stored for long periods of time This sophisticated device is ideal for recharging and maintaining the 12 volt battery in your boat car garden trac...

Page 2: ...WARNINGS RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OF LEAD ACID BATTERIES IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION THEREFORE IT IS OF UTMOST IMPORTANCE THAT EACH...

Page 3: ...p corrosion from coming in contact with your eyes Add distilled water in each cell until the battery acid reaches levels specified by the battery manufacturer if applicable Do not overfill For all bat...

Page 4: ...d battery the 2603 may require considerable time to bring the batteries to full charge When the green LED turns on your battery is already at or near full charge and the charger is now maintaining the...

Page 5: ...support or too many batteries attached to charger 2 Red LED is off due to a DC overload or a DC short 3 One or more defective batteries 4 Component failure 1 Install a higher Amperage battery Charger...

Page 6: ...e Charger s AC Ground Connections are Intact then test Dockside power 2 Contact Guest Service for info 8 SPECIFICATIONS Output Charging 12 Volts DC min 3 Amps Maintaining 25 to 60 milliamps 13 5 VDC 0...

Page 7: ...r receipt is required Hand written receipts are not accepted for warranty proof of purchase There is no other expressed warranty Implied warranties including those of merchantability and or fitness fo...

Reviews: