3.3.1.2
Temperature ranges
The following temperature ranges and humidity apply:
Product life phase
Temperature range
Air humidity
Transport
-10 to +60 °C
Operation
-20 to +70 °C
Up to and at 85 %,
condensation forma-
tion is not permissible
Storage
-10 to +40 °C
Up to 75 %
Table 3-2
Temperature ranges: FlexxPump
3.3.1.3
IP protection class
The product conforms to the protection class IP65.
3.3.1.4
Operating pressure
The operating pressure is 70 bar and is monitored electronically by counter-
pressure measurement.
3.3.2
Splitter
3.3.2.1
Temperature ranges
The following temperature ranges and humidity apply:
Product life phase
Temperature range
Air humidity
Transport
-10 to +60 °C
Operation
+10 to +80°C
Up to and at 85 %,
condensation forma-
tion is not permissible
Storage
-10 to +40°C
Up to 75 %
Table 3-3
Temperature ranges: Splitter
3.3.2.2
Accuracy of the lubricant distribution
The accuracy of the lubricant distribution is ±10%. The accuracy is valid up to
a pressure difference of less than 6 bar.
Product description
OPERATING MANUAL Automatic lubrication system
FlexxPump 404DLS
99079191943154059_v10.0_
EN-US
29