Service
Any technical questions?
Complaint?
Do you need spare
parts or operation manual?
Go to our website
www.guede.com
and the section
Service
will help you quickly and without bureaucracy. Please, help us
to help you. In order to identify your device in case of
complaint, please indicate serial number, order number and
year of manufacture. All information is available on the
product label. To have all information always at hand, put
them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
Failures – causes - remedies
Failure
Cause
Remedy
Engine not running
1.
No power supply to machine.
2.
Power supply interrupted by thermal sensor.
1.
Check the power supply and the feeder cable;
contact an electrician to help you.
2.
Wait for 5-10 min before starting the machine
again.
Engine keeps switching
off when being operated
1.
Thermal sensor of the engine is defective.
2.
Engine protection keeps switching off due to
overloading.
1.
Ask an electrician to do the replacement.
2.
Wait until the engine has cooled down and start
the machine again after 5-10 min.
Overloading causes
1.
Feeder cable is too long or has too small
cross section.
2.
Circular-saw blade is not sufficiently sharp.
3.
Circular-saw blade teeth point to wrong
distribution.
1.
Use an extension cable with cross section of 1.5
mm²
2.
Sharpen the circular-saw blade.
3.
Ask a professional to provide appropriate
distribution.
Charred workpiece
1.
Circular-saw blade is blunt.
1.
Sharpen or replace the circular-saw blade.
15
Summary of Contents for GTK 721
Page 2: ...1 2 3 a b 4 2...
Page 3: ...a b 5 6 7 8 3...