Unit
Generator GSE 6700
Synchronous generator with wheel undercarriage, low oil shut off, carrying frame, 12-volt battery electric start (battery not included).
Matching battery:
12V 17Ah gel battery
L180 mm x B75 mm x H170 mm
With AVR (automatic voltage regulation for stable performance)
The automatic voltage regulator supplies the connected consumers always with the required voltage.
A critical point of separate induction appliances is the machine start up input. With start up output, 3-5 multiple of the
connected unit nominal output should be observed
Appliance description (pic. A)
1. Frame
2.
Sockets 2x 230 V and 1x 400 V
3. Oil
filler
4.
Oil drain plug
8. Engine
switch
9.
Oil control light
10. Overload
switch
11. Tank
12. Recoil
start
13. Start-up
unit
14.
Air filter housing
15. Fuel
cock
18. Generator
cover
19. Fuel
indicator
20. Tank
cover
22. Choke
23. Ground
connection
24. Electric
start
25. Battery
case
26. Wheel
undercarriage
27. Voltage
selector
Warranty
A warranty period of 12 months applies to commercial use and 24 months apply to private use and commences on the day of
purchase of the device.
Warranty applies exclusively to failures due to defective material or workmanship. An original sale slip with indication of date of sale
must be presented in case of claiming for the warranty rights.
Warranty does not cover unprofessional use such as device overload, violent use, damage caused by third party or foreign materials,
failure to comply with operations and assembly manual, and normal wear and tear.
General Safety Instructions
Prior to the initial use of the unit, the operating instructions should be read completely. If in doubt with regard to connection and
operation of the unit, consult the manufacturer (servicing department).
FOLLOW THE INSTRUCTIONS BELOW CAREFULLY IN ORDER TO SECURE A HIGH DEGREE OF SAFETY:
CAUTION!
•
Ask a certified electrician to check the connection and grounding when connecting the generator to a house
supply.
•
The generator in operation should always be earthed via a grounding pin!
•
Always place the generator on a firm, flat base.
•
Do not use the generator in closed spaces. Exhaust fumes can be deadly..
•
Do not cover the generator with anything.
•
Do not touch the generator with wet hands.
•
Do not operate in damp locations.
•
Do not connect two generators together.
12