65
Expert PDU Energy 8311
© 2022 GUDE Systems GmbH
Specifications
ip6 manual gatew ay show
show s manual IPv6 gatew ay address
3
ip6 manual dns {1..2} set "{ip_address}"
sets manual IPv6 DNS server address
ip6 manual dns {1..2} show
show s manual IPv6 DNS server address
3
ipacl
enters cmd group "ipacl"
ipacl ping enabled set {OFF=0|ON=1}
enables ICMP ping on/off
ipacl ping enabled show
show s if ICMP ping enabled
ipacl enabled set {OFF=0|ON=1}
enable IP filter on/off
ipacl enabled show
show s if IP filter enabled
ipacl filter {ipacl_num} set "{dns_name}"
sets IP filter {ipacl_num}
ipacl filter {ipacl_num} show
show s IP filter {ipacl_num}
linesensor
enters cmd group "linesensor"
linesensor all {field_list} show
show s energy sensors according field list of all
line sensors
5
linesensor {line_num} {field_list} show
show s energy sensors according field list of one
line sensor
5
linesensor {line_num} {energy_sensor} value
show
show s energy sensor of given line
5
linesensor {line_num} ovp show
show state of Overvoltage Protection
linesensor {line_num} counter reset
resets energy metering counter
linesensor {line_num} label set "{name}"
sets line meter to label
linesensor {line_num} label show
show s label of line meter
linesensor {line_num} {energy_sensor} events
set {OFF=0|ON=1}
enables events on/off
linesensor {line_num} {energy_sensor} events
show
show s if events are enabled
linesensor {line_num} {energy_sensor} events
type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5}"
enables different event types
linesensor {line_num} {energy_sensor} events
type show
show s w hat event types are enabled
linesensor {line_num} {energy_sensor} maxval
set {float}
sets maximum value for line meter
linesensor {line_num} {energy_sensor} maxval
show
show s maximum value for line meter
linesensor {line_num} {energy_sensor} minval set
{float}
sets minimum value for line meter
linesensor {line_num} {energy_sensor} minval
show
show s minimum value for line meter
linesensor {line_num} {energy_sensor} hyst set
{float}
sets hysterese value for line meter
linesensor {line_num} {energy_sensor} hyst
show
show s hysterese value for line meter
linesensor {line_num} {energy_sensor} publish
mode set {NONE=0|INTERVAL=1|DELTA=2|
INTERV_DELTA=3}
sets publish mode
linesensor {line_num} {energy_sensor} publish
mode show
show s publish mode
linesensor {line_num} {energy_sensor} publish
mqtt retain set {OFF=0|ON=1}
sets mqtt retain
linesensor {line_num} {energy_sensor} publish
mqtt retain show
show s if mqtt retain set
linesensor {line_num} {energy_sensor} publish
timer set {num_secs}
sets publish time interval
linesensor {line_num} {energy_sensor} publish
timer show
show s publish time interval
linesensor {line_num} {energy_sensor} publish
delta set {float}
sets publish delta value
linesensor {line_num} {energy_sensor} publish
delta show
show s publish delta value
linesensor {line_num} events set {OFF=0|ON=1}
LEGACY - enables events on/off
L
linesensor {line_num} events show
LEGACY - show s if events are enabled
L
linesensor {line_num} events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
LEGACY - enables different event types
L
Summary of Contents for 8311-1
Page 2: ...2 Expert PDU Energy 8311 2022 GUDESystems GmbH...
Page 5: ...Device Description...
Page 11: ...11 Expert PDU Energy 8311 2022 GUDESystems GmbH Device Description...
Page 12: ...Operating...
Page 22: ...Configuration...
Page 45: ...Specifications...
Page 80: ...Support...
Page 85: ...85 Expert PDU Energy 8311 2022 GUDESystems GmbH Index Timer 35 Timer Configuration 35 TLS 54...