![GÜDE Expert Power Control 8031 Series Manual Download Page 10](http://html.mh-extra.com/html/gude-0/expert-power-control-8031-series/expert-power-control-8031-series_manual_2277890010.webp)
10
Expert Power Control 8031/8035
© 2021 GUDE Systems GmbH
Device Description
electronics and power ports with failure detection (permanently triggered thermal fuse).
The state of the protection is indicated on the front panel by a flash.
·
An invisible flash means that the protection is active, a red flash symbolizes that the
overvoltage protection fails. (Revision 1 device)
·
An green flash means that the protection is active, a red flash symbolizes that the
overvoltage protection fails. (Revision 2 device)
In addition, the status of the overvoltage protection can be seen on the Webpage
(HTTP) and acquired with SNMP. Each surge protection module is designed that it can
derive a practical unlimited number of voltage pulses in normal installation environ-
ments. In an environment with many energy rich surge pulses it can result in perman-
ent loss of function due to aging of the overvoltage protection element.
Recovering of the overvoltage protection function can only be performed by the
manufacturer of the device. In the normal case, the device will continue to work even
after the failure of the protective function.
A signaling via E-Mail, Syslog or SNMP trap occurs only once during operation, ex-
actly at the moment in which the protection fails. In addition, at the start up of the
device a message is generated, when the overvoltage protection is not active.
1.6
Technical Specifications
Interfaces
1 x Mains supply (IEC C20, max.16 A)
1 x Ethernet port (RJ45)
1 x Serial connector (D-SUB, RS232)
2 x RJ45 for external sensor
Load Outputs
8031-1 / 8035-1
8 x Load Outputs (IEC C13, max. 10 A)
Load Outputs
8031-2 / 8035-2
8 x Load Outputs (IEC C13 Lock, max. 10 A)
Load Outputs
8031-3 / 8035-3
8 x Load Outputs (
CEE 7/3 type F
, max. 16 A)
Load Outputs
8031-4 / 8035-4
8 x Load Outputs (type G, BS 1363, max. 13 A)
Network connectivity
10/100 MBit/s 10baseT Ethernet
Protocols
TCP/IP, HTTP/HTTPS, SNMP v1/v2c/v3,
SNMP traps, Syslog, E-Mail (SMTP)
Power Supply
internal power supply (100-240 V AC / -15% /
+10%, 50-60 hz)
Overvoltage Protection: 20mm / 250J varistor disk (300V AC)
·
single peak current for 20/80us pulse: 10000 A
·
max. clamping voltage 20/80us pulse, Ipk = 100 A: 775 V
Environment
·
Operating temperature
·
Storage temperature
·
Humidity
0°C - 50 °C
-20°C - 70 °C
0% - 95% (non-condensing)
Case
powder coated, galvanized steel sheet
Measurements
19" (inches), 1 Rack Unit, (Depth 195 mm)
Weight
approx. 2.9 kg (
8031
)
approx. 3.0 kg (
8035
)
Summary of Contents for Expert Power Control 8031 Series
Page 2: ...2 Expert Power Control 8031 8035 2021 GUDE Systems GmbH ...
Page 5: ...Device Description ...
Page 14: ...Operating ...
Page 24: ...Configuration ...
Page 51: ...Specifications ...
Page 92: ...Support ...