background image

12

13

• 

To track a new OLAS transmitter it needs to be switched on and brought into ‘Close’ range of the 

Guardian hub. This is around 0.5 metres. If it is not automatically tracked move it closer to the 

Guardian hub. 

• 

Once the OLAS transmitter is automatically tracked the Guardian hub will beep twice.  

• 

Open the OLAS mobile app.

• 

Select the Guardian from the device selection page.

• 

All OLAS transmitters that are being tracked will be indicated on the home page. 

• 

Use the homepage to check the battery life of the OLAS transmitters. 

• 

Customise the OLAS transmitters name.

• 

Check OLAS tags battery status.

• 

Enable/disable cut-off switch for individual OLAS transmitters.

• 

Pause OLAS transmitters.

• 

Pause all tracking.

• 

Press the control switch once.

• 

The number of tracked OLAS transmitters is indicated with a single beep sound signal and one 

green flash per transmitter. Up to 25 transmitters can be tracked.

• 

Connect the OLAS mobile app to the Guardian. 

• 

Navigate to the home screen. 

• 

Any non-tracked OLAS transmitters within range of the Guardian will appear on the home screen 

greyed out. 

• 

Click on the right-hand side of the tag and select track. 

• 

The Guardian hub will beep twice to indicate a tag has been tracked. 

• 

To track a previously tracked OLAS transmitter it needs to be switched on and brought into ‘Near’ 

proximity which is around 3 metres away. If it is not automatically tracked move it closer to the 

Guardian hub. 

• 

When the OLAS transmitter is automatically tracked the Guardian hub will beep twice.  

3. TRACKING A NEW OLAS TRANSMITTER

4. TRACKING A PREVIOUSLY TRACKED OLAS TRANSMITTER

5. TRACKING AN OLAS TRANSMITTER USING THE OLAS MOBILE APP

6. CHECKING LOGGED OLAS TRANSMITTERS (without the OLAS mobile app)

7. CHECKING LOGGED OLAS TRANSMITTERS (with the OLAS mobile app)

8. OLAS MOBILE APP FEATURES (basic)

9. PAUSE TRACKING

10. SWITCHING OFF THE GUARDIAN

11. STOP TRACKING AN OLAS TRANSMITTER (without the OLAS mobile app)

12. STOP TRACKING OLAS TRANSMITTER (with the OLAS mobile app)

• 

Press the control switch for 2 seconds, release the control switch after a single beep.

• 

When in Paused state the control switch will flash green for 3 seconds ON/ 3 seconds OFF followed by 

a single beep sound signal. 

• 

Press the control switch once to restart tracking.

NOTE: if you have removed an OLAS transmitter whilst the Guardian is in paused state it will beep 3 times and 

remain in the Paused state. 

• 

The OLAS T2 can be adjusted using the OLAS mobile app so that it either cuts the engine and 

triggers the alarm when it is switched off (default) or it disconnects silently.  

NOTE: if the OLAS T2 is allocated as a Smart Key it will cut the engine and activate Smart Lock. 
• 

To remove any OLAS transmitter without using the OLAS app the Guardian will need to be switched 

off. 

• 

Once the Guardian is switched off, switch off the transmitters you wish to stop tracking. The 

Guardian will ‘forget’ these devices.

• 

Switch the Guardian back on and it will track those OLAS transmitters that are still switched on and 

within range. 

• 

Open the OLAS mobile app.

• 

Select the Guardian from the device selection page.

• 

All OLAS transmitters that are being tracked will be indicated on the home page. 

• 

Click on the right hand of the OLAS transmitter box to cycle it though the different operating states. 

Once it is in Paused state and it appears greyed out then the OLAS transmitter can be switched off 

and it will be removed from Tracking without activating an alert. 

• 

The Guardian can be switched off at any point by pressing the control switch for 4 seconds.

• 

The control switch will illuminate red with a long beep before switching off. 

13. LOW BATTERY ALERT

• 

A low battery alert will be initiated by the Guardian when an OLAS tag’s battery level goes below 

20%.

• 

The alert is indicated by a red flash every 10 seconds on the control switch and the Guardian Hub.

• 

The alert will remain until the battery is charged (OLAS T2) or changed (OLAS Tag).

• 

You can check which OLAS tag has low battery using the OLAS app.

• 

Once you have located the tag you can:

a. Pause the Guardian, charge or change the battery and restart tracking.
b. If the OLAS tags battery is below 10% the Guardian hub will start to beep once every 5 minutes.
c. Switch off the Guardian, switch off the OLAS tag and then restart the Guardian.
d. Pause the OLAS tag in the OLAS mobile app and then switch off the OLAS tag.

Summary of Contents for EXPOSURE LAS

Page 1: ...PUG2...

Page 2: ...0 0 19 0 16 0 12mm FEMALE MOULDED WITH CABLE 4 CORE AWG 20 35 0 35 0 84 0 4 2 37 5 83 5 Control Switch with green and red indication LED Control switch cable Guardian Hub Internal emergency light Inte...

Page 3: ...required For optimum performance the mobile device and the Guardian should be located at least 0 5 metres from any equipment transmitting radio signals including VHF Radios antennas and cables Extens...

Page 4: ...es the close to stop system 5 Connect the purple wire to the remaining kill switch wire if your system uses the open to stop system NOTE ONLY two signal wire should be connected 6 Close off the remain...

Page 5: ...ill switched ON and has been automatically tracked skip to point 8 6 Switch the OLAS Tag ON by pressing its button for 4 seconds Hold the OLAS Tag close to the Guardian The Guardian hub will beep twic...

Page 6: ...t Pause all tracking Alert only Paused OPERATION MANUAL Index 1 Start up or returning to the vessel 2 No OLAS transmitter Warning 3 Tracking a new OLAS transmitter 4 Tracking a previously tracked OLAS...

Page 7: ...n in Paused state the control switch will flash green for 3 seconds ON 3 seconds OFF followed by a single beep sound signal Press the control switch once to restart tracking NOTE if you have removed a...

Page 8: ...in the top left hand corner of the home screen 3 lines ii Select Solo Mode iii Enter in Your Number this will be sent to your emergency contact so that they can try to make contact after receiving an...

Page 9: ...metal boats will require the Guardian box to be mounted externally SPECIFICATION Power Current 10 32V 13 17mA Vessel length 50ft Tracked Transmitters up to 25 Weight 100 grams Size 92 x 90 x 38 mm LED...

Page 10: ...is running in the foreground to enable maximum response time It can take up to 30 seconds for the system to respond if the phone is in locked mode Test the Connection Whilst In Dock Test the connecti...

Page 11: ...EXPUG18 2 Contact Address Ultimate Sports Engineering Ltd Unit 4 Bury Mill Farm Bury West Sussex RH20 1NN United Kingdom www exposureolas com...

Reviews: