background image

  

  3 

 

DCR2 Specification 

 

Electrical Rating 

Input 

AC 220V  50/60Hz 

Max. Current 

2A 

Power 

100W 

Standby Power 

<2W 

 

Motor 

Type 

DC 24V 

Max. Capacity 

1000N 

 

Recommended Lifting Forces 

Max. Lifting Force 

60kg 

Rated Lifting Force 

40kg 

 

Door Type 

Max. Door Size 

20.5m

Max. Door Height 

4.6m 

Door Travel Limits 

4.5 turns of door drum approx. 

 

Courtesy Light 

Light Source 

6 x Ultra Bright LEDs 

Lighting Time 

2.5 minutes 

 

Transmitter 

Frequency 

433MHz 

Operation Range 

50m (open field) 

Coding Type 

Fixed-code 

Battery 

12V (A23 Alkaline) x 1 

 

Features 

Soft opening and closing 
Safety reverse on closing and stop on opening 

Digital interface for RH/LH setting, force adjustment, etc. 

 

Miscellaneous 

Operating Temperature 

-20

o

C ~ +50

o

Dimension (mm) 

434 L x 248 W x 190H 

Weight 

5.4kg approx. 

Summary of Contents for DCR2

Page 1: ...DCR2 ROLLER DOOR OPERATOR Installation Instructions and Owner s Manual READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION Installer Permanently attach manual to the wall HSOMU03A 1...

Page 2: ...t Saddle x1 set Anti Coning Clip x2 sets Operator Unit Remote Handset x2 Wireless Wall Button x1 Weight Bar mounting screw set x1 Manual Safety Label Optional Accessories Items and quantity may differ...

Page 3: ...Travel Limits 4 5 turns of door drum approx Courtesy Light Light Source 6 x Ultra Bright LEDs Lighting Time 2 5 minutes Transmitter Frequency 433MHz Operation Range 50m open field Coding Type Fixed c...

Page 4: ...oor Check that there is sufficient side clearance to fit the operator unit as below listed Door Type Minimum side clearance A Series 1 25mm deep tracks 90mm AA Series 2 50mm deep tracks 115mm All door...

Page 5: ...sh the Emergency Release handle to disengage the motor drive ONLY when the drive is switched OFF and if possible when the door is fully closed Do not use the sensitivity adjustments to compensate for...

Page 6: ...posite the end to which the operator is to be fitted is tightened securely This U bolt holds all the spring tension on the door once the other U bolt is released 5 Slide drive unit onto shaft as shown...

Page 7: ...t Backup Bat Auto Close Timer function will only work when Photo Eye System is properly installed To activate Auto Close Operation Turn the knob towards for maximum delay time of 2 5 minutes To deacti...

Page 8: ...n setting according to the illustrations below The corresponding LED is on upon key input View View 3 Press RADIO SET button to confirm setting The OK LED is on with 2 beeps x2 Caution Make sure the d...

Page 9: ...hen the door reaches the desired up limit position 3 During limit setting mode press UP or DOWN to fine tune to desired UP limit position or 4 When the door is at the desired UP limit position press L...

Page 10: ...desired down limit position 3 During limit setting mode press UP or DOWN to fine tune to desired down limit position or 4 When the door is at the desired DOWN limit position press LIMIT button once O...

Page 11: ...e installa tion 1 Both UP and DOWN LEDs are on after limit setting press the FORCE button once to enter Sensitivity Auto Learning mode 2 The door will open and stop at UP limit for 2 seconds 3 Door wi...

Page 12: ...g is completed 1 2 Enter Force Setting UP or 3 x2 To adjust DOWN Force Confirm 1 To adjust DOWN force press FORCE button once UP LED is on then press FORCE button again within 5 seconds DOWN LED is on...

Page 13: ...r within a 30 seconds timeframe 2 Press any button on the transmitter within 30 seconds 3 OK LED flashes once and operator beeps twice acknowledging the transmitter is set x2 To DELETE ALL transmitter...

Page 14: ...door automatically 1 2 3 x2 Courtesy Light Beeper Responses Operation Condition Courtesy Light Beeper Responses Operator is initially plugged in no travel limits stored Flash x 5 Reconnecting power wi...

Page 15: ...tion for correct balance not binding Adjust if necessary Spray silicone lubricant into tracks Do not grease Check adjust safety sensitivity setting Check Limits BANGS HARD ON TRACK STOPS WHEN FULLY OP...

Page 16: ...16 Parts Breakdown 2 1 3 8 9 10 4 11 5 12 6 7 19 6 15 13 21 18 14 16 20 23 17 22 24 25 27 26 28...

Page 17: ...ransformer Mounting Plate 19 Drive Gear 6 Transformer Protection 20 Clutch Dock 7 Transformer 21 Clutch Release 8 U bolt 22 Finger Dog 9 Saddle 23 Clutch Retainer 10 Saddle Mounting Plate 24 Sungear D...

Page 18: ...ase or 6 000 cycles whichever occurs first for the electronics and mechanics A cycle means one opening and closing cycle of the door 2 the remote controlled transmitters and accessories included with...

Page 19: ...rol of Guardian Automation o Consumer Goods Components such as globes accessories batteries and other consumable parts are not covered by this warranty What will void this warranty Guardian Automation...

Page 20: ......