Prior to use, plan your system:

MAXIMUM spacing between Friction Fit Brackets: 8’.

1. Upon complete assembly and installation, all leading edges of fall hazards must be blocked,
or a supplemental Fall Protection system MUST be used in combination with, but never
connected to, the applicable Fall Prevention system.

2. Selected work area must be free of all hazards, including, but not limited to, debris, rot, decay,
cracking, and hazardous materials. NEVER install Friction Fit Brackets on top of gravel or other
loose or slippery surfaces. Guardrail systems must be installed a MINIMUM 10’ from power lines
and all other electrical hazards.

3. All guardrail posts, guardrails, and all other equipment must be selected and deemed
compatible by a Competent Person. All guardrails MUST be compatible 2” x 4“ or 2” x 6“
construction grade lumber, or compatible snap-on metal rails.

4. Toprails must be 42” (+/- 3”) above the work surface or, if used in stilt work applications, 42”
plus height of stilts.

5. Midrails must be halfway between the top edge of the guardrail system and the working level
(not the toeboard).

6. All intermediary rails (not the top rail or the midrail) must not allow for gaps greater than 19”.

7. Toeboards are REQUIRED on surfaces with slopes more than 4/12 (vertical/horizontal).

8. Toeboards are REQUIRED if a risk exists for tools, equipment, materials, or other substances to
fall down to a lower level.

9. Toeboards must be a minimum 3½” from their top edge to the work surface, and must not
have greater than ¼” clearance between their bottom edge and the work surface.

10. Lay out the job by measuring and spacing the location of Friction Fit Brackets on the work
surface. Failure to properly measure and plan ahead may result in having to move and reinstall
system components.

Friction Fit Brackets MUST be installed flush against substrate, and must allow

guardrail posts to be positioned perpendicular to work surface.

Substrate MUST be deemed compatible with Friction Fit Brackets by a Competent Person.

Summary of Contents for 15026

Page 1: ...Product Name Friction Fit Bracket Instruction Manual Part 15026 Do not throw away these instructions Read and understand these instructions before using equipment...

Page 2: ......

Page 3: ...n Friction Fit Bracket This manual must be read and understood in its entirety and used as part of an employee training program as required by OSHA or any applicable state agency This and any other in...

Page 4: ...r sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Competent Person A highly trained and experienced person...

Page 5: ...he maximum allowable free fall distance for lanyards must not exceed 6 No free fall allowed for non LE SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Forces app...

Page 6: ...ence of cracks sharp edges deformation corrosion excessive heating alteration excessive wear fraying knotting abrasion and absence of parts Equipment that fails inspection in any way must immediately...

Page 7: ...it Bracket for deficiencies including but not limited to corrosion deformation pits burrs rough surfaces sharp edges cracking rust paint buildup excessive heating alteration and missing or illegible l...

Page 8: ...ystems are placed around the leading edges of any and all fall hazards to prevent a worker from going over an edge and may be used in substitute of Fall Protection or safety netting systems Installati...

Page 9: ...r deceleration distance user height length of lanyard SRL and all other applicable factors Diagram shown is an EXAMPLE fall clearance calculation ONLY Swing Falls Prior to installation or use make con...

Page 10: ...g and withstand minimum loads of 3 600 lbs See the following for examples of compatible incompatible connections Connector closed and locked to D ring OK Two or more snap hooks or carabiners connected...

Page 11: ...6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6 from the leading edge Y the wo...

Page 12: ...ction 6305 S 231st St Kent WA 98032 phone 800 466 6385 fax 800 670 7892 www guardianfall com 10 Materials zinc plated steel 5 4 Clamp Bolts Zinc plated steel 1 2 13 x 5 Grade 5 Clamp Plates Clamp Bolt...

Page 13: ...or compatible snap on metal rails 4 Toprails must be 42 3 above the work surface or if used in stilt work applications 42 plus height of stilts 5 Midrails must be halfway between the top edge of the g...