Installation and Use

Components and Specifications

Type A anchorage connector.

Minimum permitted service
temperature: -30° F.

5,000 lb. MBS (minimum
breaking strength).

Materials: powder-coated steel.

Fastener

Installation

Holes

(60 total,

30 per side)

MINIMUM substrate requirements:

• Wood: 3/4” CDX plywood (for all fasteners)
and 3“ support beam (for minimum 4 fasteners).
• Metal: 20 gauge.
• Concrete: 6” (must be 2,000 psi or greater).

*Wood and metal installations compliant with
OSHA only. Concrete installation compliant with
both OSHA and ANSI.

Adjustable Skyhook Anchor MUST install flush against substrate.

1. Determine desired location for anchor; ensure location is free of debris, rot, decay, cracking, and hazardous
materials. NEVER install on gable ends, fascias, rake ends, overhangs, bottom cords, collar boards, spliced
sections, or substrate incapable of withstanding application minimum loads. If unable to determine suitable
installation location, consult jobsite Qualified Person.

2. Make considerations for eliminating or minimizing swing fall hazards.

3. Adjustable Skyhook Anchor is compatible with roof pitches from flat to 12/12. ALWAYS measure roof pitch
prior to installation. NEVER use Adjustable Skyhook Anchor incompatible with roof pitch. 

4. Adjustable Skyhook Anchors MUST be placed a MINIMUM 10’ from all leading edges of fall hazards.

5. Ensure all fasteners are those supplied by Guardian Fall Protection, or are deemed compatible by a
Competent Person. All fastener installation holes MUST be filled. Installations must be done directly on
substrate, and never through any intermediary substrates.

- If installing onto wood, a minimum of 4 fasteners must fully embed into truss or underlying support beam.

- If installing onto concrete, use qty. 15 fasteners per side. Fill two full rows closest to center (on each side).

- If removing and reinstalling a Adjustable Skyhook Anchor, fully inspect the anchor according to instruction
inspection specifications. DO NOT reuse if any signs of damage or defects are found. ALWAYS use new
fasteners for each new installation application.

Substrate fastener requirements:

• Wood: #14 x 10, 2” wood deck screws. Qty. 60.
• Metal: #14 x 10, 2” metal deck screws. Qty. 60.
• Concrete: ¼“ x 2¾” concrete bolts. Qty. 30 

Connection point

Summary of Contents for 00342

Page 1: ...stand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 7 Product Specific Applications 1 2 Limitations 2 3 Components and Specifications 4 Maintenance Cleaning and Storage 5 Inspection 5 Installation and Use 4 5 Inspection Log 6 Labels 7 ...

Page 2: ...lso might include state specific regulations Consult regulatory agencies for more information on personal fall arrest systems and associated components Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited degree or certification and with extensive experience or sufficient profes...

Page 3: ...st a fall before the user strikes the ground or an obstruction When calculating fall clearance account for a MINIMUM 3 safety factor deceleration distance user height length of lanyard SRL harness stretch and all other applicable factors Diagram shown is an example fall clearance calculation ONLY Swing Falls Prior to installation or use make considerations for eliminating or minimizing all swing f...

Page 4: ...ding Edge Y Working Distance Along Roof Edge Either Direction X Working Angle From Perpendicular Ø 6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6 from the leading edge Y the working distance X is 8 in each direction from the perpendicular which translates to a 53 working angle...

Page 5: ...ing or minimizing swing fall hazards 3 Adjustable Skyhook Anchor is compatible with roof pitches from flat to 12 12 ALWAYS measure roof pitch prior to installation NEVER use Adjustable Skyhook Anchor incompatible with roof pitch 4 Adjustable Skyhook Anchors MUST be placed a MINIMUM 10 from all leading edges of fall hazards 5 Ensure all fasteners are those supplied by Guardian Fall Protection or ar...

Page 6: ...IMMEDIATELY remove Adjustable Skyhook Anchor from service if defects or damage are found or if exposed to forces of fall arrest Ensure that applicable work area is free of all damage including but not limited to debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUS...

Page 7: ...son before fall protection equipment is selected The analysis of the workplace must anticipate where workers will be performing their duties the routes they will take to reach their work and the potential and existing fall hazards they may be exposed to Fall protection equipment must be chosen by a Competent Person Selections must account for all potential hazardous workplace conditions All fall p...

Page 8: ...uce the effects of suspension trauma DO NOT REMOVE LABELS If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE User must inspect prior to EACH use Competent Person must complete formal inspection every 12 months Competent Person to inspect and initial INSPECTION GRID Date of First Use __________________ Product lifetime is indefinite as long as equipment passes pre use and Competent Perso...

Reviews: