G
uar
di
an
F
al
l P
ro
te
ct
io
n
63
05
S
. 2
31
st
St
.,
Ken
t,
W
A
9
80
32
2
Product Specific Applications
Personal Fall Arrest:
Beamer 2000 may be used to support a MAXIMUM 1 personal fall arrest
system (PFAS) for use in Fall Arrest applications. Structure must withstand loads applied in the
directions permitted by the system of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’ if
used in combination with equipment explicitly certified for such use. Applicable D-ring: Dorsal.
Restraint:
Beamer 2000 may be used in Restraint applications. Restraint systems prevent workers
from reaching the leading edge of a fall hazard. Always account for fully deployed length of
lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system of
at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on surfaces with
slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal, Chest, Side, Shoulder.
!
WARNING
Use of equipment in unintended applications may result in serious
injury or death. Maximum 1 attachment per connection point.
For all applications: worker weight capacity range
(including all clothing, tools, and equipment) is 130-420 lbs.
Limitations
Fall Clearance:
There must be sufficient
clearance below the anchorage connector
to arrest a fall before the user strikes the
ground or an obstruction. When calculating
fall clearance, account for a MINIMUM 2’
safety factor, deceleration distance, user
height, length of lanyard/SRL, harness
stretch and all other applicable factors.
Diagram shown is an example fall
clearance calculation ONLY.
Swing Falls:
Prior to installation or use, make
considerations for eliminating or minimizing
all swing fall hazards. Swing falls occur when
the anchor is not directly above the location
where a fall occurs. Always work as close to in
line with the anchor point as possible. Swing
falls significantly increase the likelihood of
serious injury or death in the event of a fall.
Rescue/Confined Space:
Beamer 2000 may be used in Rescue/Confined Space applications.
Rescue systems function to safely recover a worker from a confined location or after exposed to a
fall. There are various configurations of Rescue systems depending on the type of rescue.
Structure must withstand loads applied in the directions permitted by the system of at least
3,000 lbs. No free fall is permitted. Applicable D-rings: Dorsal, Chest, Shoulder.
Fall clearance calculation shown based on standing
worker falling directly in-line with anchor point.
Always consider potential swing fall and other
hazards when calculating fall clearance.
*Eliminate Swing Fall whenever
possible! If Swing Fall exists,
always account for additional
fall clearance.
1.5’
2’
12’
5’
Anchor Point
at Foot Level
12’ Free Fall
Lanyard
Anchor Point
Level w/Dorsal D-ring
6’ Free Fall
Lanyard
2’