GUARDEON G-OP-SCPIR-K Installation And Use Manual Download Page 4

IR detection LED

Alarm LED

TAMPER

 anti-opening

Terminals

JUMPER 

tilt

DIPS 

switch

7

8

COMPONENT LOCATION

BT-LINK-S2 Module 

Connector

TRIMMER 

(IR and MW 

sensitivity)

I

TECHNICAL

Power supply

12 V

DC

Absorption 

*

Stand-by: about 14 mA

Alarm: about 12 mA

Autonomy (estimated) 

**

-

Stabilization Time (at power-up)

About 2 minutes (with LED blink)

Quiet Time between detections

-

Detection technologies

n. 1 Infrared head

n. 1 Pulsed microwave @ 24 GHz head

Thermal compensation

Automatic compensation

-

-

-

-

Detection area 

Max 12 linear meters (adjustable: 3 m ÷ 12 m)

7.5 ° radial opening (IR)

105 ° radial opening (MW)

-

-

Sensitivity

Uni

 ed setup (trimmer) from 30% (min) to 100 

% (max)

Radio frequency / range

-

Anti-masking

Active infrared

Radio signals

-

Wired outputs

OptoMOS N.C. type

(open an alarm occours or if 
power is o

 )

Max 40 V

DC

 / 100 mA

Alarm

Tamper

Masking

LEDs

1 red LED (IR head detection)

1 blue alarm LED

Temperature / Humidity

-40 ÷ +70 °C / 95 % (relative)

Case

ABS antiUV 

Dimension (H x W x D) 

128mm x 41mm x 48mm

Internal space for transmitter (H x W x D)

-

Accessories included

n. 1  wall bracket

*

 All the data are approximate, for sensor in NORMAL mode at operating temperature of 21 °C. 

**

 Mean value for 10 detections-alarms/day + supervision.

GUARDEON Security Systems ApS.                 Vandtårnsvej 100                 2860 Søborg                 CVR: 37769568                 T: +45 72 17 00 28                 W: guardeon.dk                 E: info@guardeon.dk 

Summary of Contents for G-OP-SCPIR-K

Page 1: ...d BT LINK S supplied separately The sensor adapts to environmental conditions thanks to a sophisticated thermal compensation system The sensor detects over an area with a maximum length of 12 m and a width of 7 5 Fig A DETECTION AREA A B TOP VIEW SIDE VIEW installation at 2 2m high Fig B 12 m 1 2 To change the detection area change the inclination of the sensor and adjust the microwave and infrare...

Page 2: ...in figure E 3 4 SIDE VIEW installation at 3m height with inclined sensor fig C The wall mounting bracket is angled to ensure correct installation fig F Position the sensor spaced from the wall following the rule from 0 to 3 meters mount the sensor about 20 cm from the wall from 3 to 6 meters mount the sensor about 40 cm from the wall from 6 to 9 meters mount the sensor about 60 cm from the wall from ...

Page 3: ...se perform the following steps make holes for fixing plugs H1 screw the wall base to the wall plugs H2 H3 break through the cable gland with a screwdriver and pass the wiring H4 screw the sensor to the wall base H5 close and tighten the sensor cover H6 SENSOR PARTS Wall plate Anti mask Head IR Cover Head MW Tamper H Cable entry 1 2 3 4 5 Details Explanation H1 Fischer anchors 6mm 2pcs H2 Washer 4 h...

Page 4: ...ng IR 105 radial opening MW Sensitivity Unified setup trimmer from 30 min to 100 max Radio frequency range Anti masking Active infrared Radio signals Wired outputs OptoMOS N C type open an alarm occours or if power is off Max 40 VDC 100 mA Alarm Tamper Masking LEDs 1 red LED IR head detection 1 blue alarm LED Temperature Humidity 40 70 C 95 relative Case ABS antiUV Dimension H x W x D 128mm x 41mm x...

Page 5: ...ND TRIMMER MANDATORY PLACE THE COVER TO PERFORM TESTS WAIT AT LEAST 3 SECONDS THE SENSOR READS NEW SETTINGS THE SENSOR WORKS ONLY WITH THE COVER ON ITS PLACE INSTALLATION WHAT TO KNOW ABOUT POWER ON If the sensor is already powered before proceeding it is necessary to switch off the power supply and keep the anti removal tamper pressed for about 3 seconds in this way the circuit is completely disch...

Page 6: ...via VIEW SENSOR DIPS 1 4 remain active After memorizing a configuration using VIEW SENSOR DIP3 must remain ON even after the WALK TEST has ended If you place DIP3 in ON but you have not loaded a configuration via VIEW SENSOR the sensor will use the hardware configuration DIP3 OFF REMOTE PROGRAMMING DISABLED the sensor configuration is done by DIPS and trimmers This manual mainly explains the HARDWARE ...

Page 7: ...cted INFRARED AND MICROWAVE INDEPENDENT ADJUSTMENT VIEW SENSOR is the innovative application developed on Windows and Android platform that facilitates the installation of outdoor sensors VIEW SENSOR allows you to adjust the sensor optimally to better define the area you want to protect minimizing improper alarms The application allows you to perform a walk test completely innovative through wirele...

Reviews: