background image

7,5°

CURTAIN OUTDOOR SENSOR DOUBLE TECHNOLOGY 

WITH ANTIMASK

INSTALLATION AND USE MANUAL

G-OP-SCPIR-K is a dual technology curtain sensor designed to protect access (such as doors, 

windows, etc.), balconies, and walls.

G-OP-SCPIR-K is able to create an electronic wall which, if it is crossed, generates an alarm.

The detection is entrusted to a passive infrared sensor and a 24 GHz microwave.

The combination of these two technologies, together with a sophisticated detection algorithm, 

allows to discriminate improperly alarms with care.

Equipped with anti-opening tamper, inclinometer and anti-masking, it is supplied with a practical 

wall bracket.

G-OP-SCPIR-K supports the innovative Wireless Walk Test and Programming System, composed of 

the VIEW SENSOR software and the mod. BT-LINK-S (supplied separately).

The sensor adapts to environmental conditions thanks to a sophisticated thermal compensation 

system.

The sensor detects over an area with a maximum length of 

12 m

 and a width of 

7.5 °

 (Fig. A)

DETECTION AREA

A

B

TOP VIEW

SIDE VIEW 

(installation at 2.2m high) (Fig. B)

12 m

1

2

To change the detection area, change the inclination of the sensor and adjust the microwave 

and infrared ranges.

12 m

2,2m

READ CAREFULLY THIS MANUAL BEFORE INSTALL YOUR NEW ALARM 

SYSTEM. KEEP THIS MANUAL FOR FUTURE REFERENCE.

ONLY QUALIFIED TECHNICIAN MUST INSTALL THIS DEVICE.

INSTALLER MUST FOLLOW CURRENT REGULATIONS.

THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY IMPROPER USE OF 

THE PRODUCT, INCORRECT INSTALLATION OR FAILURE TO COMPLY WITH 

INSTRUCTIONS OF THIS MANUAL AND THE LAW REGARDING ELECTRICAL 

SYSTEMS.

G-OP-SCPIR-K

ver.: 2019-03-01_1_fr

GUARDEON Security Systems ApS.                 Vandtårnsvej 100                 2860 Søborg                 CVR: 37769568                 T: +45 72 17 00 28                 W: guardeon.dk                 E: [email protected] 

Summary of Contents for G-OP-SCPIR-K

Page 1: ...d BT LINK S supplied separately The sensor adapts to environmental conditions thanks to a sophisticated thermal compensation system The sensor detects over an area with a maximum length of 12 m and a width of 7 5 Fig A DETECTION AREA A B TOP VIEW SIDE VIEW installation at 2 2m high Fig B 12 m 1 2 To change the detection area change the inclination of the sensor and adjust the microwave and infrare...

Page 2: ...in figure E 3 4 SIDE VIEW installation at 3m height with inclined sensor fig C The wall mounting bracket is angled to ensure correct installation fig F Position the sensor spaced from the wall following the rule from 0 to 3 meters mount the sensor about 20 cm from the wall from 3 to 6 meters mount the sensor about 40 cm from the wall from 6 to 9 meters mount the sensor about 60 cm from the wall from ...

Page 3: ...se perform the following steps make holes for fixing plugs H1 screw the wall base to the wall plugs H2 H3 break through the cable gland with a screwdriver and pass the wiring H4 screw the sensor to the wall base H5 close and tighten the sensor cover H6 SENSOR PARTS Wall plate Anti mask Head IR Cover Head MW Tamper H Cable entry 1 2 3 4 5 Details Explanation H1 Fischer anchors 6mm 2pcs H2 Washer 4 h...

Page 4: ...ng IR 105 radial opening MW Sensitivity Unified setup trimmer from 30 min to 100 max Radio frequency range Anti masking Active infrared Radio signals Wired outputs OptoMOS N C type open an alarm occours or if power is off Max 40 VDC 100 mA Alarm Tamper Masking LEDs 1 red LED IR head detection 1 blue alarm LED Temperature Humidity 40 70 C 95 relative Case ABS antiUV Dimension H x W x D 128mm x 41mm x...

Page 5: ...ND TRIMMER MANDATORY PLACE THE COVER TO PERFORM TESTS WAIT AT LEAST 3 SECONDS THE SENSOR READS NEW SETTINGS THE SENSOR WORKS ONLY WITH THE COVER ON ITS PLACE INSTALLATION WHAT TO KNOW ABOUT POWER ON If the sensor is already powered before proceeding it is necessary to switch off the power supply and keep the anti removal tamper pressed for about 3 seconds in this way the circuit is completely disch...

Page 6: ...via VIEW SENSOR DIPS 1 4 remain active After memorizing a configuration using VIEW SENSOR DIP3 must remain ON even after the WALK TEST has ended If you place DIP3 in ON but you have not loaded a configuration via VIEW SENSOR the sensor will use the hardware configuration DIP3 OFF REMOTE PROGRAMMING DISABLED the sensor configuration is done by DIPS and trimmers This manual mainly explains the HARDWARE ...

Page 7: ...cted INFRARED AND MICROWAVE INDEPENDENT ADJUSTMENT VIEW SENSOR is the innovative application developed on Windows and Android platform that facilitates the installation of outdoor sensors VIEW SENSOR allows you to adjust the sensor optimally to better define the area you want to protect minimizing improper alarms The application allows you to perform a walk test completely innovative through wirele...

Reviews: