1. 

I

Illustration to buttons 

 

Fig.1

Control Panel

 

 

 

MIN

Frequency up- searching / Minute

 

  On-off/Setting confirm

 

HOUR

  Frequency down- searching/ Hour

 

  Radio or DVD/TV Switch/ On-off

 

+

  Volume up/ Set switch

 

  Blower On-off

/℉ or ℃ Switch

 

-

  Volume down/ Open

 

  Spa Light On-off

 

MEM

  Radio channel Memory/ Lock

 

Surfing pump 1    On-off

 

SET

  Radio channel read / Close

 

 

view pump 2      On-off

 

    Lasting Circulation Cleaning On-off

 

Surfing pump3 +circulation pump On-off/Set   

Circulation Cleaning Time

 

  Heating On-off

 / Set Pre-heating 

  Set Temperature

 

Note

 

.The functions listed with blue letters only works on the condition of on-off 

 

II

Function Summary

 

1

Max. with 6 KW heating system, set pre-heating, set and display temperature

 

2

With 3 surfing pumps,1 circulation pump, 1 view pump, and 1 blower.

 

3

Ozone, Spa lights. 

Summary of Contents for SPA-513

Page 1: ...1 HOT TUB Model SPA 513 OPERATING INSTRUCTION ...

Page 2: ...Surfing pump 1 On off SET Radio channel read Close view pump 2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with blue letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set pre heating set and display temperature 2 ...

Page 3: ...oller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and circulation cleaning function is off 2 Lock memory Mode optional function The memory lock will start work by pressing MEM key in the status of power off when the spa has not been adjusted for a period of 30 minutes When the memory locked key is pressed TWICE M...

Page 4: ...g the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and then the circulation works on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1 minute when pressing MIN each time and the minutes could be added continually The adjustment ...

Page 5: ... this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre h...

Page 6: ... heat On 图 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Continual time of preheating 4 Preset temperature 5 Finished ...

Page 7: ...will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 45 5 When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is...

Page 8: ...30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turned off automatically once the preset time is finished or Pressing the key can stop directly 8 Operation to Power ON OFF Pressing the key from power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen...

Page 9: ...emorize the present radio frequency in different channel The channel of max is 10 Name of channel is 0 9 Ⅵ The volume can be changed by pressing key SET VOL and OPEN 11 Operation of Pump The Button operates pump 1 The Button PUMP2 operates pump 2 The button PUMP3 operates pump 3 When Circulation cleaning and heating including preheating turn on circulation pump will be working automatically 12 Ope...

Page 10: ...can not start up However the corresponding signals will flash on the LCD 18 Prevent freezing function The heater circulation pump will work automatically once the water temperature is below 5 when the water temperature is reach at 10 heating will stop This function is only available while the spa is on normal power supply IV Electric parameters 1 Performance index Rated voltage 220V 50Hz Maximum w...

Page 11: ...perating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage system has to be provided to deal with overflow water Details of how to follow the wiring rules for example specifying that parts are installed in the correct zone and that equipotential bonding is carried out WARNING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protec...

Page 12: ...ange a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...