background image

©

2007 GTO, Inc.

R3200INST

     

re

v - 9/10/07

WARNING!

This equipment is similar to other gate or door equipment and meets or exceeds 

Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has 

hazards associated with its use and therefore by installing this product the installer 

and user accept full responsibility for following and noting the installation and 

safety instructions. Failure to follow installation and safety instructions can result 

in hazards developing due to improper assembly. You agree to properly install this 

product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, 

indirect, incidental, special or consequential damages or loss of profits whether 

based in contract tort or any other legal theory during the course of the warranty 

or at any time thereafter. The installer and/or user agree to assume responsibility 

for all liability and use of this product releasing GTO, Inc. from any and all 

liability.  If you are not in agreement with this disclaimer or do not feel capable 

of properly following all installation and safety instructions you may return this 

product for full replacement value.

READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before 

attempting to install and use this automatic gate operator.  This gate operator 

produces a high level of force.  Stay clear of the unit while it is operating and 

exercise caution at all times.

All automatic gate operators are intended for use on vehicular gates only.

This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as 

established and made effective March 1, 2000, by Underwriters Laboratories Inc.

Installation Manual

 

for installing the GTO/PRO SW-3200XL with the 

GTO/PRO SW-3000XL in a dual application

FOR PROFESSIONAL INSTALLATION ONLY!

®

DC-SERIES

®

DC-SERIES

For more information on GTO/PRO’s full line of automatic gate openers and access controls visit our website at www.gtopro.com

Summary of Contents for SW-3000XL

Page 1: ...all liability and use of this product releasing GTO Inc from any and all liability If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and s...

Page 2: ...ss locations not servicing the general public in which unauthorized access is prevented via supervision by security personnel The GTO PRO 3000 3200 Gate Operators are intended for use with vehicular s...

Page 3: ...r page 17 Installation of the Closed Position Stops page 18 Mounting the Control Box page 20 Connecting the Operator Power Cables page 21 Powering the System page 22 Solar Chart page 22 Connecting the...

Page 4: ...ocks and other access control products These optional accessories see the enclosed GTO PRO Accessory Catalog are available The GTO PRO 3000 3200 Operators feature adjustable obstruction sensing This s...

Page 5: ...ns and warnings in this manual are identified with this warning symbol The symbol identifies conditions that can result in damage to the operator or its components serious injury or death Because GTO...

Page 6: ...size of gate its frequency of use and the proper class rating 2 Make sure the dual gate has been properly installed and swings freely in both directions Repair or replace all worn or damaged gate hard...

Page 7: ...nched 3 Devices such as contact sensors safety edges and non contact sensors photo beams provide additional protection against entrapment 4 If push buttons or key switches are installed they should be...

Page 8: ...ay to it at least once per month 7 Service the gate and gate operator regularly Grease hinges spray push pull tube with high quality silicone spray and replace the battery every 3 5 years 8 To operate...

Page 9: ...as one that transmits radio frequency RF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by buildi...

Page 10: ...when installing the GTO PRO 3000 3200 Operators Furthermore a walk through gate must be installed if pedestrian traffic is expected near the vehicular gate We recommend using the GTO Bulldog Pedestria...

Page 11: ...ification and manual operation instruction label 1 installed on right side of control box Logo and warning labels 2 installed on each side of operator housing Logo and warning labels 2 installed on ea...

Page 12: ...ver Mounting Screw 5 E Z GATE OPENER Master Gate Operator 1 PRO3000ARMXL 3 8 Bushings 2 Transformer 1 RB570 Battery 1 RB500 Warning Signs 2 GTO Transmitter 1 RB741 1 KEEP CLEAR Gate may move at any ti...

Page 13: ...Closed Position Stop Plate 1 2 Receiver Mounting Screw 5 Slave Operator Arm 1 PRO3200ARMXL 3 8 Bushings 2 Gate Bracket 1 BRACKET BOX HB3000 HARDWARE BAG H101P Warning Signs 2 1 KEEP CLEAR Gate may mov...

Page 14: ...the diameter of the fence post see page 14 A horizontal or vertical cross member or mounting plate may be needed to mount the operator to the gate See page 13 Weatherproof cover for transformer if ou...

Page 15: ...ing point Maximum stroke 16 Adjustable auto close timer OFF to 120 s and obstruction sensitivity Power terminal block accommodates a transformer or solar panels not both DIP switches simplify setup of...

Page 16: ...he diagram shown below is an example of a pull to open installation on a chain link fence and dual gates Mounting the operators on a masonry column requires special procedures see Column Installation...

Page 17: ...quare should be made of metal instead of wood so that it will remain stable while the operator is moving the gate On round posts of 6 diameter or larger the post pivot bracket may not be necessary for...

Page 18: ...8 Lock Washer Post Bracket Assembly 3 8 Washer NOTE The following steps are intended for pull to open gate installations If you are mounting your operators on a push to open gate e g a gate on a slop...

Page 19: ...and readjust the pivot bracket until you can achieve these important clearances With the post pivot bracket in the optimum position for clearance and freedom of movement reattach the operator to the g...

Page 20: ...olt cutters NOTE In cases where the fence post has a diameter larger than 6 threaded rods or carriage bolts longer than 8 not supplied must be used Step 10 Mark reference points for bolt holes on the...

Page 21: ...ry Installing the Slave Operator Step 12 Install the SLAVE operator on the remaining gate leaf by repeating Step 3 through Step 11 starting on page 14 After you have mounted the SLAVE operator proceed...

Page 22: ...LAVE gate and gate operator Illustration A Closed Position Stop Plate mounted horizontally on metal post with U bolts SLAVE Gate Frame MASTER Gate Frame TOP VIEW FRONT VIEW Step 1 Attach the horizonta...

Page 23: ...e the closed position stop plate toward the ground stop until they touch Illustration C Once you have moved the stop plate to the correct position tighten its hardware completely NOTE For a push to op...

Page 24: ...nt electrical interference RED wire to POSITIVE terminal BLACK wire to NEGATIVE terminal RED BLACK MIN MAX 12 V Battery Included Space for optional second 12 Volt battery see Accessory Catalog Battery...

Page 25: ...into the control box Retighten strain relief on the black sheath of the power cable until the power cable locks into place Insert the stripped wires of the power cable into the appropriate terminals o...

Page 26: ...gauge dual conductor multi stranded direct burial wire see page 22 and the Accessory Catalog Do not run more than 1000 feet of wire ON OFF Switch OPTIONAL Solar Panels and Gate Activity The table and...

Page 27: ...lor Tighten set screws against exposed end of wires A dab of household petroleum jelly on each terminal will help prevent corrosion ORG BLUE WHT GRN BRN RED MASTER INPUTS BLK SOLAR or 18 VAC ORG BLUE...

Page 28: ...it and damaging the control board Step 6 Strip 1 2 of insulation from the ends of the low voltage wire Attach these stripped ends to the transformer terminals A dab of household petroleum jelly on ea...

Page 29: ...3 seconds The maximum turn the potentiometer all the way clockwise auto close time is 120 seconds Main DIP Switch Settings MODES DIP Switch 1 Soft Start Stop ON Soft start enabled factory preset OFF...

Page 30: ...TE S CLOSED POSITION LIMIT IS NOW PROGRAMMED Step 5 Activate your openers again by pressing the entry transmitter button Your gates should now be moving from the fully open positions toward their clos...

Page 31: ...your CLOSED LIMIT settings and follow Steps 1 7 again CLEARING PROGRAMMED CLOSED LIMIT SETTING If you make a mistake and set the limit at the wrong position press your transmitter to return the gates...

Page 32: ...t responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user s authority to operate the equipment Obstruction Sensitivit...

Page 33: ...losing 4 EXIT OPEN Typically for use with exit loop or wand Activation of this input will open the gate if it s not already at the open position Activation of this input while at open limit will resta...

Page 34: ...tector GTO PRO Push Button Control GTO PRO Automatic Gate Lock According to Application According to Application GTO PRO Vehicle Sensor Refer to Vehicle Sensor manual for additional connections Edge S...

Page 35: ...are in the closed position Step 2 After verifying that you have the best position for the post pivot bracket insert the 5 16 x 1 3 4 bolt through the aligned holes of the post bracket and post pivot...

Page 36: ...Setting the Open Position Limit Step 1 Confirm that the power switch is in the ON position and the gates are in the CLOSED POSITIONS Step 2 Activate your openers by pressing the entry transmitter but...

Page 37: ...n achieved proceed to step 6 Step 6 Repeat step 3 for the other gate that has not been set in step 3 Step 7 Press the transmitter button and allow the gates to return to the closed position BOTH YOUR...

Page 38: ...ad 1 beep then 2 beeps Master Motor Terminals Shorted Connections to Master Inputs Master Arm Power Cable Motor Circuit Board 1 beep then 3 beeps Slave Motor Terminals Shorted Connections to Master In...

Page 39: ...mote If the remote works the problem is the accessory Status clear 6 blinks Open Edge Terminal Shorted Disconnect edge sensor photo beam or any other accessory wired to this terminal Try the remote If...

Page 40: ...ner is necessary the Service Department will assign a Return Goods Authorization RGA number to you for warranty repair 4 Securelypackthecomponent s authorizedforreturntothefactory Includeacopyof proof...

Page 41: ...voltage at panel and control box 12 V 7 amp hour Battery_ ______________________12 0 to 13 5 Vdc 7 0 Ah or Two 12V 7 amp hour Batteries if using solar power Charging circuit _________________________...

Page 42: ...is recommended that you place a steel plate between the operator mounting brackets and masonry surface for additional strength B If a push to open installation is impossible due to traffic hazards ter...

Page 43: ...quipment with all GTO PRO systems 12 Volt battery included Digital Keypad F310 The specially designed digital keypad can be easily installed as a wireless or wired keypad It can be programmed to use u...

Page 44: ...aintaining the battery included with the GTO PRO 3200XL gate operator This is the only transformer approved for use with all UL325 GTO PRO gate operator systems Garage Door Receiver RB709U The Garage...