SLAVE CAB
Wire from
Automatic GTO Lock
GTO Lock:
For use exclusively with GTO Lock (FM143 or FM144).
Connecting other devices to these terminals may cause incorrect
operation and void your warranty.
GTO Lock Connection:
Connect the red and black leads from the lock to the GTO LOCK
terminal on the GTO/PRO® SW2502 control board. You do not
use the lock's control board when using GTO's board.
Connecting GTO Automatic Gate Lock
If not connecting gate lock skip to next section.
Aux:
• These 2 terminals are normally open 'dry-contact'
(no voltage) relay ouput.
• These 2 terminals are ON (shorted) whenever the gate is
moving and OFF (opened) otherwise.
• These 2 terminals maximum rating is 24Vdc, Amp.