Normal Keypad Operation:

•  If the user enters a 4-digit code that is matched to one of the 25 stored codes. The STATUS light should blink rapidly 

indicating that it is sending command to operator. 

•  No more than 20 key presses are allowed to obtain the 4-digit entry code. 

Example

1234 is one of the codes stored in one of the memory location. 

The user can enter “x1234” or “xxxxxxxxxxxxxxxx1234” and the gate should be activated (x is any key). If more than 

20 key presses is entered without matching one of the codes then the unit’s STATUS light should be flashing rapidly 

and no entry will be accepted for the next 40 seconds.  The user must not enter any code for at least 40 seconds before 

the unit returns to normal operation; otherwise it remains in this “lock-down” mode. Once the user enters a matched 

code, any subsequent key press within the next 40 seconds will cause the keypad to send command to gate opener.

Keying Indication Summary:

 

     Keying Error Alert Indication 

   Keying accepted confirmation Indication

Master Code Setting 

Speaker: continuous Beep for 2 seconds 

Speaker: Beep – Beep – Beep

 

STATUS light: rapid flashing  

STATUS light: no light, no flashing

Permanent Entry Code 

Speaker: continuous Beep for 2 seconds 

Speaker: Beep – Beep – Beep

 

STATUS light: rapid flashing 

STATUS light: no light, no flashing

Temporary Entry Code  

Speaker: continuous Beep for 2 seconds 

Speaker: Beep – Beep – Beep

 Setting  

STATUS light: rapid flashing 

STATUS light: no light, no flashing

Entry Code Matching 

Speaker: continuous Beep for 2 seconds 

Speaker: Beep – Beep – Beep

  

 

 (after non-matching 20 keying)  

 

STATUS light: rapid flashing 

STATUS light: no light, no flashing