background image

 

place the UPS away from other units at least 20 cm to avoid interference. DO NOT operate the UPS 

where the temperature and humidity is outside the specific limits. (Please check the specs for the 

limitations.) 

Plug in the AC input cord to the wall outlet. For the best results, 

suggest charging the battery at least 4 hours before initial use. The 

unit charges its battery while connecting to the utility. 

Plug in the loads to output receptacles on the rear panel of the UPS. 

Simply turn on the power switch of UPS unit, then devices 

connected to the UPS will be protected by UPS unit. 

To surge protect a network connection, connect a network cable from the wall jack outlet to the IN 

jack of the UPS.    Then connect a network cable from the OUT jack of the UPS to the network 

device.   

UPS equipped with communication port allows monitoring and controlling from computer screen.   

Connect one end of a communication cable to your PC and the other to the com port at the rear of 

the UPS. 

 

ViewPower is an UPS power management software, allowing users to control and monitor UPS 

straightly from PC monitor.    Insert ViewPower software CD or download ViewPower software from 

http://www.power-software-download.com

 to your hard drive.    Follow on-screen instructions to 

complete the software installation. 

 

After computer is restarted, ViewPower is geared and presents as an orange plug icon located in 

the system tray at the right-bottom corner.

 

 
 
 
 
 
 
 
 
 
 
 
 
 

To turn on the UPS, press power switch lightly.    To turn off the UPS, please press power switch 

again. 

 

 

!

"

#

PC615N-650 and PC615N-850 UPS are equipped with Green Power Function.    For saving power 

and protecting battery, the method of deep discharging protection is adopted on inverter mode. 

Trouble-shooting

Use the table below to solve minor problems.    If any abnormal situations occur that are not listed 
above, please call service technician for assistance. 

Problem 

Possible Cause 

Solutions 

Low battery. 

Charge the UPS at least 6 hours. 

Battery fault. 

Replace the battery with the same type of 
battery. 

No LED display on 
the front panel. 

The UPS is not turned on. 

Press the power switch again to turn on the 
UPS. 

Alarm continuously   
sounds when the   
mains is normal. 

The UPS is overload. 

Remove some loads first. Before reconnecting 
equipment, please verify that the load matches 
the UPS capability specified in the specs. 

The UPS is overload. 

Remove some critical load. 

Battery voltage is too low. 

Charge the UPS at least 6 hours. 

When power fails, 
back-up time is 
shortened. 

Battery defect. It might be due to high 
temperature operation environment, or 
improper operation to battery. 

Replace the battery with the same type of 
battery. 

The mains is normal, 
but LED blinks.. 

Power cord is loose. 

Reconnect the power cord properly. 

Specifications

Model 

650 

850 

1000 

1500 

2000 

CAPACITY 

650VA/ 

360W 

850VA/ 

480W 

1000VA/ 

600W 

1500VA/ 

900W 

2000VA/ 

1200W 

INPUT

 

Voltage 

110/120 VAC or 220/230/240 VAC 

Voltage Range 

81-145 VAC / 162-290 VAC 

OUTPUT

 

Voltage Regulation 

+/-10% 

Transfer Time 

Typical 2-6 ms, 10 ms max. 

Waveform 

Simulated Sine Wave 

BATTERY

 

Type & Number 

12V/7AHx1 

12V/9AHx1 

12V/7AHx2 

12 V/9 AH x 2 

Charging Time 

4-6 hours recover to 90% capacity 

PHYSICAL

 

Dimension, DxWxH, (mm)   

287x100x142 

350x146x 160 

397x146x205 

Net Weight (kgs) 

4.25 

4.90 

8.0 

11.1 

11.5 

Environment

 

Humidity 

0-90 % RH @ 0-40° C (non-condensing) 

Noise Level 

Less than 40 dB 

MANAGEMENT

 

USB 

Supports Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008 

* Product specifications are subject to change without further notice.

 

Reviews: