18
If the force value at the end of the 5s measurement period (
F
End
) exceeded 80 N
and the dynamic time (
t
dyn
) exceeded 0.75 s, the LEDs within the second, third
and fourth display segment flash.
Â
Display of the value
t
dyn
:
►
After measurement press the control button once. The display shows the
value for the dynamic time in milliseconds (ms).
L
The LED within the second display segment is lit for orientation.
Measurement result:
F
dyn
= 326 N
t
dyn
> 0,75 s
t
dyn
= 740 ms = 0,74 s
F
End
> 80 N