background image

 

GTD-LYS300 (CW/WW) User Manual 

13 

Problem 

Possible Cause 

Suggested Correction 

power cables, luminaire power socket). 

socket for proper connection. 

No  DC  voltage  from  switching  power 
supply. 

Check if the switching power supply has DC voltage output. Replace 
the switching power supply. 

No response or 
wrong response 
to the 
commands of 
the control 
system 

DMX  cables  disconnected  from  fixture’s 
DATA IN connector. 

Connect DMX cable to the fixture’s DATA IN connector. 

Open  circuit  or  short  circuit  fault  in  the 
DMX cables. 

Replace DMX cables as required. 

Wrong DMX address for the fixture in the 
control system. 

Ensure  the  address  in  “Run  setting  >  Address  Setting  >  Address”of 
the fixture is consistent with the address in the control system. 

Misuse  in  “Channel  setting  >  Channel 
Mode” of the fixture. 

Choose  the  channel  mode  in  “Channel  setting  >  Channel  Mode”  of 
the fixture as required by the user. 

Malfunctioning  of  DMX  cannon  input 
/output  connectors.  No  input/output 
voltage to the main control board of the 
fixture. 

Troubleshooting the DMX XLR signal plate of the fixture, replace the 
main control board of the fixture. 

LED lamp off

 

There  is  no  signal  output  to  the  main 
control board PWM. 

Replace the main control board or repair.

 

No output to the drive board LED +/ LED- 
or  drive  board  over-current,  check  line 
connector if contact bad. 

Reconnect the terminal, replace the driver board

 

Normal end of LED lamp life, bad welding 
or poor heat dispersion.

 

Repair  or  replace  LED  light  source  or  replace  the  whole  piece  of 
aluminum board, remove the cooling system failure.

 

Decreased 
brightness, 
uneven pattern 
projections 

LED lamp aging, check the service time of 
LED  light  source,  test  LED  drive  board’s 
current. 

Replace  the  LED  light  source  or  adjust  the  drive  board’s  current. 
Reduce LED’s brightness.

 

Excessive dusts or smudges on the effect 
assembly,  focus  module  and  objective 
lens. 

Follow the instructions stated in this user manual to clean the effect 
assembly, focus module and objective lens. 

Damaged  or  deformed  effect  assembly, 
focus module or objective lens. 

Replace the damaged or deformed components. 

 

 

Summary of Contents for GTD-LYS300

Page 1: ...LED Fresnel Spotlight GTD LYS300 CW WW User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Page 2: ...companies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained w...

Page 3: ...ries 5 Product introduction 6 Installation 6 Clamps installation 6 Device installation 6 Power Control connection 7 Power connection 7 Control connection 7 Testing 7 Control panel 8 Menu structure 8 DMX protocol 9 Technical specification 10 Cleaning and maintenance 11 Troubleshooting 12 System wiring diagram 14 Spare parts list 14 Appendix 1 15 ...

Page 4: ...LY Do not expose fixture for rain and moisture It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should b...

Page 5: ... to ensure performance of the fixture Disconnect the fixture from power before changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixtu...

Page 6: ...rapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along with all the accessories Close the cover Only 3 layers are allowed when p...

Page 7: ...direction The fast lock clamp gives a quick and easy lock on the truss Warning Use one clamp when mounting the fixture Fasten the screw properly and connect a safety cable to fixture Device installation 1 Make sure there is no damage on the clamps or safety cables before installation 2 The clamp is mounted on the handle of the fixture Horizontally insert the clamp into the mounting holes of the ha...

Page 8: ...output 3 pin optional as shown below Connection between the console and fixture and between fixtures must be made with 2 core screened DMX signal cable Maximum connecting distance of signal cable is 150 meters Additional DMX512 signal amplifier is recommended for longer distance Connect the Console s DMX OUTPUT to the first fixture s DMX INPUT then the first fixture s DMX OUTPUT to the second fixt...

Page 9: ... DOWN to change the value of the selected function increase or decrease Press MENU to return to the previous menu or exit LED indicators Power on RED power LED indicator on Signal on Green DMX indicator on No Signal Green DMX indicator off Menu structure LYS300 Menu Structure Level 1 Level 2 Level 3 Level 4 Info Run setting Address Setting Address 001 XXX Setting the DMX address Device Info Time I...

Page 10: ...ntage Function Default DMX Value Standard 4ch 1 Intensity 0 255 0 0 100 0 No light Full light 0 0 2 Zoom 0 255 0 0 100 0 Near Far 0 0 3 Dimmer Mode 0 5 0 0 2 0 M0 600Hz Dimming curve1 fade dimming 0 0 6 11 2 4 4 3 M1 600Hz Dimming curve2 snap dimming 12 17 4 7 6 7 M2 1200Hz Dimming curve1 fade dimming 18 23 7 1 9 0 M3 1200Hz Dimming curve2 snap dimming 24 29 9 4 11 4 M4 600Hz Dimming curve1 fade d...

Page 11: ...ntrol channels DMX 2 Display LCD display Dimmer 0 100 Physical Installation Weight 11 6kg 17 lbs IP rating IP20 Material Aluminum steel plastic Mounting points 12mm holes for G Clamp Minimum distance to combustible materials 1 64ft 0 5m Minimum distance to illuminated surfaces 3 28ft 1m Dynamic effects Pan Tilt movement Manually adjustable Thermal Operating range 14 F to 113 F 10 C to 45 C Startup...

Page 12: ...GTD LYS300 CW WW User Manual 11 EMC EN 55103 1 2009 EN 55103 2 2009 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2013 Safety EN 60598 2 17 1989 A2 1991 Photometric LYS300 CW LYS300 WW ...

Page 13: ...mp appears dim this normally indicates that it is reaching the end of its life span and should be changed at once Aged LED lamps run to the extremity of their life might explode If fixture does not function check the fuse on the power socket of the fixture Replace the fuse of the same specification if it is blown The fixture is equipped with thermal protection device that will switch off the LED l...

Page 14: ...nput output voltage to the main control board of the fixture Troubleshooting the DMX XLR signal plate of the fixture replace the main control board of the fixture LED lamp off There is no signal output to the main control board PWM Replace the main control board or repair No output to the drive board LED LED or drive board over current check line connector if contact bad Reconnect the terminal rep...

Page 15: ...5A 1 LED LY 300W7575D30 Color Temperature 3200 100K White with thermistor 10K LEDdriver 100B 1 5802030106A 1 LCR0100B Signal caton board 2 5802910001A 1 SKL0002A L N V 12 V 48 GND GND L G N LED LED Fan Switch power fan Focus motor DMX Signal Caron Focusing magnetic susceptibility LED Drive Transfer Board High Power LED Display Power cable1 0mm2 Switch power EDS360 4812P GTD LYS300 fuse Power ...

Page 16: ...GTD LYS300 CW WW User Manual 15 Appendix 1 ...

Page 17: ...GTD LYS300 CW WW User Manual 16 Notes P N 1502011086A Time Aug21th 2017 ...

Reviews: