background image

 

GTD-L6119P User Manual 

15 

Troubleshooting 

Problem 

Possible Cause 

Suggested Correction 

No response 
after connected 
to A/C power 

Power switch not turned on. 

Turn on power switch. 

Take out the fuse and check if it is blown. 

Locate  the  blown  fuse.  Remove  the  broken  fuse.  Insert  a 
replacement fuse of the correct amperage. 

Abnormal  A/C  input  (A/C  power  socket, 
power cables, luminaire power socket). 

Replace AC power socket and power cables, and then adjust power 
socket for proper connection. 

No  DC  voltage  from  switching  power 
supply. 

Check if the switching power supply has DC voltage output. Replace 
the switching power supply. 

No response or 
wrong response 
to the 
commands of 
the control 
system 

DMX  cables  disconnected  from  fixture’s 
DATA IN connector. 

Connect DMX cable to the fixture’s DATA IN connector. 

Open  circuit  or  short  circuit  fault  in  the 
DMX cables. 

Replace DMX cables as required. 

Wrong DMX address for the fixture in the 
control system. 

Ensure  the  address  in  “Run  setting  >  Address  Setting  >  Address”of 
the fixture is consistent with the address in the control system. 

Misuse  in  “Channel  setting  >  Channel 
Mode” of the fixture. 

Choose  the  channel  mode  in  “Channel  setting  >  Channel  Mode”  of 
the fixture as required by the user. 

Malfunctioning  of  DMX  cannon  input 
/output  connectors.  No  input/output 
voltage to the main control board of the 
fixture. 

Troubleshooting the DMX XLR signal plate of the fixture, replace the 
main control board of the fixture. 

LED lamp off

 

There  is  no  signal  output  to  the  main 
control board PWM. 

Replace the main control board or repair.

 

No output to the drive board LED +/ LED- 
or  drive  board  over-current,  check  line 
connector if contact bad. 

Reconnect the terminal, replace the driver board

 

Normal end of LED lamp life, bad welding 
or poor heat dispersion.

 

Repair  or  replace  LED  light  source  or  replace  the  whole  piece  of 
aluminum board, remove the cooling system failure.

 

Decreased 
brightness, 
uneven pattern 
projections 

LED lamp aging, check the service time of 
LED  light  source,  test  LED  drive  board’s 
current. 

Replace  the  LED  light  source  or  adjust  the  drive  board’s  current. 
Reduce LED’s brightness.

 

Excessive dusts or smudges on the effect 
assembly,  focus  module  and  objective 
lens. 

Follow the instructions stated in this user manual to clean the effect 
assembly, focus module and objective lens. 

Damaged  or  deformed  effect  assembly, 
focus module or objective lens. 

Replace the damaged or deformed components. 

 

Summary of Contents for GTD-L6119P

Page 1: ...LED Wash Flood Light GTD L6119P User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Page 2: ...panies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained with...

Page 3: ... Accessories 5 Product introduction 6 Installation 6 Device installation 6 Power Control connection 7 Power connection 7 Control connection 7 Testing 8 Control panel 8 Menu structure 9 DMX protocol 10 Technical specification 12 Cleaning and maintenance 14 Troubleshooting 15 System wiring diagram 16 Spare parts list 17 Appendix 1 17 ...

Page 4: ...G Fire hazard It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Before ap...

Page 5: ...e changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for installation operation and maintenance by qualified p...

Page 6: ...sories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along with all the accessories Close the ...

Page 7: ...ition on the base of the fixture Warning Use two clamps when mounting the fixture Fasten the screw properly and connect a safety cable to fixture Device installation 1 Make sure there is no damage on the clamps or safety cables before installation 2 The clamps are mounted on the base of the fixture Horizontally insert the clamp into the mounting holes of the base Fasten the clamp tightly by a 1 4 ...

Page 8: ...fixture is correctly grounded and the electrical installation conforms to all relevant Standards Codes of Practice for Safe Electrical Work Control connection The fixture has 5 pin XLR connectors for DMX data input and output 3 pin optional as shown below Connection between the console and fixture and between fixtures must be made with 2 core screened DMX signal cable Maximum connecting distance o...

Page 9: ...of the fixture Press UP or DOWN to view or select the function menu Press ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to th...

Page 10: ...XX D 00 DXXX Display the channel value D ON ON OFF Turn on or off the Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version Edit SEPR AUTO IP01 IP10 Selecting the program that want to edit ST...

Page 11: ...light Full light 0 0 3 0 65535 0 0 100 0 Intensity fade fine LSB 4 3 Red 0 255 0 0 100 0 No light Full red 0 0 5 0 65535 0 0 100 0 Red fine LSB 6 4 Green 0 255 0 0 100 0 No light Full green 0 0 7 0 65535 0 0 100 0 Green fine LSB 8 5 Blue 0 255 0 0 100 0 No light Full blue 0 0 9 0 65535 0 0 100 0 Blue fine LSB 10 6 Rainbow Function1 0 9 0 0 3 5 No function 0 0 10 39 3 9 15 3 Rainbow scene 1 40 71 1...

Page 12: ...200K 91 101 35 7 39 6 4400K 102 112 40 0 43 9 4600K 113 123 44 3 48 2 4800K 124 134 48 6 52 5 5000K 135 145 52 9 56 9 5200K 146 156 57 3 61 2 5400K 157 167 61 6 65 5 5600K 168 178 65 9 69 8 5800K 179 189 70 2 74 1 6000K 190 200 74 5 78 4 6200K 201 211 78 8 82 7 6400K 212 222 83 1 87 1 6600K 223 233 87 5 91 4 6800K 234 244 91 8 95 7 7000K 245 255 96 1 100 0 7200K Notes Do not switch off the fixture...

Page 13: ...8 segment display Physical Installation Weight 14 5kg 32 lbs IP rating IP65 Material Aluminium steel plastic Minimum distance to combustible materials 1 64ft 0 5m Minimum distance to illuminated surfaces 3 28ft 1m Dynamic effects Pan Tilt movement Manually adjustable Strobe 1 25Hz synchronized pulse effects Dimmer 0 100 16 bit electronic linear dimming Thermal Operating range 14 F to 113 F 10 C to...

Page 14: ...GTD L6119P User Manual 13 Certification and Safety EMC EN 55103 1 2009 EN 55103 2 2009 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2013 Safety EN 60598 2 17 1989 A2 1991 Photometric ...

Page 15: ...sing of the fixture If the lens is cracked or otherwise damaged replace it immediately If the LED lamp becomes damaged or deformed in any way it must be replaced If the light from the LED lamp appears dim this normally indicates that it is reaching the end of its life span and should be changed at once Aged LED lamps run to the extremity of their life might explode If fixture does not function che...

Page 16: ... of the fixture Choose the channel mode in Channel setting Channel Mode of the fixture as required by the user Malfunctioning of DMX cannon input output connectors No input output voltage to the main control board of the fixture Troubleshooting the DMX XLR signal plate of the fixture replace the main control board of the fixture LED lamp off There is no signal output to the main control board PWM ...

Page 17: ...erproof male female signal cable fan 4 SDI0200C 1412050028A switching power supply N L FG neutral wire live wire earth wire GTD L6119P J7 J1 J4 J8 J2 J3 GND VCC 5802030046A LCR0205B J2 J4 J8 5802030055A LCR0206B J3 J7 GND VCC J5 J4 J3 J2 JC1 JC2 ESS400 5624P 24V GND 56V GND 5802010030A JC J1 LJB0217B ...

Page 18: ...are parts list Item P N Qty Notes Switching Power Supply 1412050028A 1 EDS400 5624P LED drive board 5802030046A 1 LCR0205B LED lamp board 5802030055A 1 LCR0206B Display board 5809210049A 1 L6119P 101E10 102F10 SDI0200C Appendix 1 ...

Page 19: ...GTD L6119P User Manual 18 Notes P N 1502011093A Time August 15th 2017 ...