background image

 

GTD-L3100 User Manual 

General guidelines 

 

Never open this fixture while in use. 

 

The fixture should be kept clean. 

DO NOT 

operate the fixture in extreme heat or dusty environments. Avoid contact 

with chemical liquid. 

 

This  fixture  is  a  professional  light  effect  designed  for 

INDOOR  /  DRY  LOCATIONS  ONLY

  on  stage,  in  nightclubs, 

theatres, etc. 

 

Minimum

 distance to lighted objects must be 

3.28feet (1m)

 

Maximum

 temp of the external surface 

140˚F (60˚C)

 

Maximum

 ambient temperature 

113˚F (45˚C)

 

Minimum

 distance of inflammable materials from the surface 

1.6 feet (0.5m)

 

LED lamp should be changed if damaged or distorted in shape due to extreme heat.     

 

Cover, lens or Menu Function Display with visible damages such as cracks or scratches must be replaced to ensure 

performance of the fixture.   

 

Disconnect the fixture from power before changing any parts or accessories.   

 

Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures, 

clamps, cables, auxiliary equipment, etc. Check that the cover, clamps and locks are undamaged. Certified safety 
cables must always be used when installing the fixture. 

 

The  fixture  is  only  intended  for  installation,  operation  and  maintenance  by  qualified  professional.  Instructions 
stated in the manual must be complied.   

 

The fixture must be kept in a well-ventilated place at least 50 cm away from any wall surface. Check if the fans or 

ventilation openings are unblocked.   

 

Broken or damaged cables can only be fixed or changed by certified technicians, certified local distributors or the 
manufacturer to ensure operational safety.   

 

Do  not  stick  filters  or  other  materials  onto  the  lens.  Do  not  modify  the  fixture  or  install  other  than  GTD 
manufactured parts. 

 

For questions regarding safety operation, please contact our technical personnel or call the service h8620 
61808296. 

Summary of Contents for GTD-L3100

Page 1: ...LED Cyclorama GTD L3100 User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Page 2: ...anies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained withi...

Page 3: ... 5 Product introduction 6 Installation 7 Clamps installation 7 Device installation 7 Power Control connection 7 Power connection 7 Control connection 8 Testing 8 Control panel 9 Menu structure 10 DMX protocol 11 Technical specification 13 Cleaning and maintenance 14 Troubleshooting 15 System wiring diagram 16 Spare parts list 17 Appendix 1 17 ...

Page 4: ...Do not expose fixture for rain and moisture It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be u...

Page 5: ...anging any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for installation operation and maintenance by qualified profe...

Page 6: ...oam from the top put away the accessories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along ...

Page 7: ...TD L3100 User Manual 6 Product introduction 1 LED lens 2 Base 3 Clamp mounting position 4 Manually adjustable screw 5 DMX input 6 Power switch 7 Fuse 8 DMX output 9 Power input 10 Power output 11 Display ...

Page 8: ...he truss Power Control connection Power connection Connection method L Live Brown wire E Earth Yellow Green bi color wire N Neutral Blue wire The voltage and frequency of the power source must be in compliance with the ones marked on the fixture Please apply series connection when many sets of fixtures are connected to the power source to avoid heavy load to the power source When the voltage is 11...

Page 9: ...commended for longer distance Connect the Console s DMX OUTPUT to the first fixture s DMX INPUT then the first fixture s DMX OUTPUT to the second fixture s DMX INPUT and so on It is recommended not to connect more than 32 units on a single DMX universe On the last fixture s output connect a DMX terminator The terminator is a XLR connector with a W and 120Ω resistor between the pin 2 and pin 3 as s...

Page 10: ...s ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to the previous menu or exit LED indicators Power on RED power LED indicator ...

Page 11: ...X D 00 DXXX Display the channel value D ON ON OFF Turn on or off the Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version Edit SEPR AUTO IP01 IP10 Selecting the program that want to edit STE...

Page 12: ...e fine LSB 4 3 Red 0 255 0 0 100 0 No light Full red 0 0 5 0 65535 0 0 100 0 Red fine LSB 6 4 Orange 0 255 0 0 100 0 No light Full orange 0 0 7 0 65535 0 0 100 0 Orange fine LSB 8 5 Amber 0 255 0 0 100 0 No light Full amber 0 0 9 0 65535 0 0 100 0 Amber fine LSB 10 6 Green 0 255 0 0 100 0 No light Full green 0 0 11 0 65535 0 0 100 0 Green fine LSB 12 7 Cyan 0 255 0 0 100 0 No light Full cyan 0 0 1...

Page 13: ...200 74 5 78 4 6200K 201 211 78 8 82 7 6400K 212 222 83 1 87 1 6600K 223 233 87 5 91 4 6800K 234 244 91 8 95 7 7000K 245 255 96 1 100 0 7200K 21 12 Special controls 0 39 0 0 15 3 No function 0 0 40 59 15 7 23 1 Built in program 1 60 79 23 5 31 0 Built in program 2 80 99 31 4 38 8 Built in program 3 100 119 39 2 46 7 Built in program 4 120 139 47 1 54 5 Built in program 5 140 159 54 9 62 4 Built in ...

Page 14: ...Auto ranging electronic SMPS Main fuse 250V 3 15A Control and programming Control channels DMX 21 12 Protocol DMX 512 Display 4 x 8 segment display 16 bit control Dimmer Physical Installation Weight 8kg 17 6 lbs IP rating IP20 Material Aluminum steel plastic Mounting points 12mm holes for G Clamp Minimum distance to combustible materials 1 64ft 0 5m Minimum distance to illuminated surfaces 3 28ft ...

Page 15: ...e its reliability Its lifespan mainly depends on the working environment and proper operation Should you have any questions please consult a technical engineer of GTD Lighting Notes Damage resulted from dust smoke oil or improper use is not covered by warranty Warning Disconnect the fixture from AC power and let it cool down for at least 15 minutes before opening the housing Make sure to use a sof...

Page 16: ...e to the commands of the control system DMX cables disconnected from fixture s DATA IN connector Connect DMX cable to the fixture s DATA IN connector Open circuit or short circuit fault in the DMX cables Replace DMX cables as required Wrong DMX address for the fixture in the control system Ensure the address in Run setting Address Setting Address of the fixture is consistent with the address in th...

Page 17: ... LJB0304D 1407180002A J6 FAN1 N L E power swpply FUSE Switching power supply J3 J2 J1 J1 J2 J3 J4 J8 J6 J5 J7 N L FG JF2 J5 J4 J3 J6 J4 J1 JF1 FAN2 GND VCC 28V GND 28V GND LJB0304D SCB0300B LCR0305D XLR socket fan SDI0200B GTD L3100 fan 1412050023A 56V GND ...

Page 18: ...tes LED aluminum substrate 5802010033A 2 LJB0304D LED driver board 5802030037A 1 LCR0305D Display board 5809210026B 1 L3100 101E11 102F11 103F11 SDI0200B XLR board 5802910008A 1 SKL0006B Switching power supply 1412050023A 1 EDS350 5628PN 350W EAGL Appendix 1 ...

Page 19: ...GTD L3100 User Manual 18 Notes P N 1502011034A Time May 15th 2017 ...

Reviews: