5 The pin is marked with a
blue
dot. You must pull the plates away and put
the pins into the correct holes (
1
to
4
) for your desired latitude. The actual
position (
2
) is for mid Northern/Southern latitudes,
4
is down to 20 deg,
1
is
for far North.
6 Push the RA head back into the fork base, insert the centering rings and the
locks, finally mount the DEC head.
To fine adjust elevation and azimuth use the screws indicated below.
1 turn of the elevation screw is cca 0,6 degree change in elevation.
Connecting Cables
You need to connect 3 plugs to Pulsar2 and one to the G53F. The rest is
routed internally. You also have a power plug routed to the RA head to supply
all your 12V DC equipment on the scope, without additional cables.
G53F manual ver 2.7
p6 June 2017
www.geminitelescope.com
Azimuth control
Elevation control
turn ccw to elevate
Release ¼ turn on
Both sides before
Adjusting elevation