Key:
LSB
MSB
b0
Least significant bit
Most significant bit
Maximum X or Y value at set resolution
The configuration report does not express the resolution in lines per inch or lines per
millimeter. Rather, the resolution is indicated as the total number of counts over the
length of the axis.
Example:
The tablet is the CR configuration. The resolution setting is 200 lpi. The X and Y
axis are 12 inches long. Therefore, the resolution is 2400 for each axis. The Send
Configuration report is:
Tablet Beep
Use this command if you want to disable the tablet beep. To enable it again, issue the
Reset command or repower the tablet.