4.3 Measurement Procedures

 

 

CAUTION

:  Maximum Input Voltage is 600Vrms,do not exceed 

this rating to avoid personal injuries or damage to the 
instrument. The FUNCTION switch should be set to 
the range you want to test before the operation.

  

CAUTION

:  Always ensure that the correct terminals are used 

for the type of measurement to be made. Avoid 
making connections to “live” circuits whenever 
possible.When making current measurements en-
sure that the circuit is not “live” before opening it in 
order to connect the test leads.

• 

The measurement will be shown in the LCD Display when the 
probe are connected. For Continuity Test  a continuous beeping 
sound indicates that the measured resistance is < 100

 

.

4.3.4 Frequency measurement

• 

Connect the black test lead to the “

COM

” socket and red test lead 

to  the “

+

” socket.

• 

Set the 

FUNCTION

 switch to the “

 

V Hz

” function. 

• 

The instrument default to VDC measurement. To measure 
frequency press the 

SELECT

 button momentarily twice, and the 

Hz will appear on the display. 

• 

Connect the read probe into the “

+

” input and the black probe 

into the “

COM

” input.

• 

When the frequency function is selected, the trigger level defaults 
to 1 Volt. If the readings are unstable or if there is not reading at 
all, it maybe be necesary to change the trigger level. To change 
the trigger level, press the “

RANGE

” button once to display the 

selected level, and then press the “RANGE” button within 1 
second. Every time the button is pressed the trigger level will 
change to the next value (1V, 2V, 20V and 200V).

• 

Connect the test leads across the source or circuit under 
measurement. Readout will show on the LCD display.

4.3.5 Tach (RPM) Measurement

4.3.1 DC/AC Voltage measurement

• 

Connect the black test lead to the “

COM

” socket and red test lead 

to  the “

+

” socket.

• 

Set the 

FUNCTION

 switch to the “

 

V Hz

” function. 

• 

The instrument default to DC measurement. To measure AC 
Voltages press the 

SELECT

 button momentarily. 

• 

Connect the read probe into the “

+

” input and the black probe 

into the “

COM

” input.

• 

Connect the test leads across the source or load under 
measurement. Readout will show on the LCD display.

4.3.2 DC Current measurement

• 

Connect the black test lead to the “

COM

” socket and red test lead 

to  the “

A mA

” input connector. .

• 

Set the 

FUNCTION

 switch to the “

mA

 

” function.

• 

Connect the test leads in series with the source or load under 
measurement.

• 

The instrument default to DC measurement. To measure AC 
Current press the 

SELECT

 button momentarily.

• 

Connect the test leads in series with the source or load under 
measurement. Readout will show on the LCD display.

4.3.3 Resistance measurement and Continuity Test

  

CAUTION

:  Maximum Input Voltage for this function is 600 Vrms  

do not exceed this rating to avoid personal injuries or 
damage to the instrument. Also ensure there is no  
power applied  to  the  component or circuit  and all 
capacitors are discharged.

• 

Connect the black test lead to the “

COM

” socket and red test lead 

to  the “

+

” socket.

• 

Set the 

FUNCTION

 switch to the “

” position. The instrument 

will default to Resistance measurement, to select the Continuity 
Test function press the “

SELECT

” button momentarily.

• 

Connect the test leads across the componet or circuit under 
measurement.

• 

Connect the black lead plug of the inductive pick-up into the 

COM

” socket and red lead plug to the “

+

” socket.

• 

Set the 

FUNCTION

 switch to the 

 position. 

• 

Press the SELECT button to select through “

RPM 

” for 4 

strockes, “

RPM

  ” for 2 strockes and DIS, and “

RPM

   

M

 

for 2 

strockes with waste spark ignition system engines.

• 

Open the Inductive Pick-up clamp and insert a spark plug wire 
inside, observing that the arrow on the Inductive Pick-up points 
to the spark plug, and then close the clamp making sure that the 
clamp jaws are completely close. The RPM will be shown in the 
LCD Display when the engine is running.

4.3.6 Dwell Angle Measurement

• 

Connect the black test lead to the “

COM

” socket and red test lead 

to  the “

+

” socket.

• 

Set the 

FUNCTION

 switch to the “

 

%

” position, and press 

the 

SELECT

 button once to select the 

 Dwell function.

• 

The Number of cylinders defaults to 4 (

4-C

)

Press the “

Cylinder 

/RANGE

 

switch

 

to display the cylinders setting, and immediately 

press the button again to select the number of cylinders (1 
through 12) of the engine under test.

Taking Tach 

Readings

Measuring 
resistance 
and 
continuity

M e a s u r i n g 

Voltages

Summary of Contents for CT8027

Page 1: ...and 9V battery 3 2 Electrical Specifications Accuracies are of reading number of least significant digits at 23 C 5 C less than 75 RH For DC AC current measurement the maximum current of 10 A is for 30 Sec with 5 min cool down between measurements 4 OPERATION 4 1 Instrument Description 1 Case 2 4 Digit LCD display 3 Secondary Functions Button 4 Auto Manual Select 5 Function Switch 6 Current Measur...

Page 2: ...urement Readout will show on the LCD display 4 3 2 DC Current measurement Connect the black test lead to the COM socket and red test lead to the A mA input connector Set the FUNCTION switch to the mA A function Connect the test leads in series with the source or load under measurement The instrument default to DC measurement To measure AC Current press the SELECT button momentarily Connect the tes...

Page 3: ...ain This function applies to both Port Fuel Injectors PFI and Throttle Body Injectors TBI To change the trigger level and slope please refer to Section 4 4 4 and 4 4 5 of this manual 4 4 Other Functions 4 4 1 Diode Test CAUTION Maximum Input Voltage for this function is 600 Vrms do not exceed this rating to avoid personal injuries or damage to the instrument Connect the black test lead to the COM ...

Page 4: ...or no significant meter reading changes The instrument is turned automatically ON if the FUNCTION switch is operated 4 4 9 External power lines noise filtering When the RECORD function is activated the instrument will turn off the AUTO POWER OFF function and the indicator in the display will not show To read the MAX MIN MAX MIN and AVG press the REC button to step through the recorded measurements...

Reviews: