Specification

Lithium

polymer

battery

Battery dimension

9060100

Standard capacity

7000mAh

0.2C standard

discharge

internal

resistance

≤60mΩ

3) Protection

Testing Specification

Testing Parameters

Testing Condition

Remark

Over discharge detection

2.9V

Over discharge releasing

3.1V

Over charge releasing

4.08-4.13V

Over charge testing voltage

4.15V-4.24V

4) Charging Testing

Name

Testing Specification

Testing Parameters

Testing Condition

Remark

Battery

Chargin

g

Full charge voltage

4.15V

4.24V

Charging current

2400mA±200MA

3.7V

Turning light current

150mA

Full charge indication

LED long bright

Charging state

Four LED indicator

Corresponding battery charging

flashing

Blue LED

5

Discharge Testing Parameters

Name

Testing Specification

Testing Parameters

Testing Condition

Remark

Battery

single

discharg

e

Output voltage

5.0V±0.25V

Electronic load

ripple wave

<150mVp-p

oscilloscope

output load voltage

5.0V±0.25V

Electronic load

Inputp load current

2000mA±200mA

Electronic load

Over current

3.3A-4.2A

Discharge rate

>80

PCB Conversion

efficiency

short circuit protection

Current more than 5A

150-200US

Discharge instructions

the current voltage in long bright

Instruction