Specification
Lithium
polymer
battery
Battery dimension
9060100
Standard capacity
7000mAh
0.2C standard
discharge
internal
resistance
≤60mΩ
3) Protection
Testing Specification
Testing Parameters
Testing Condition
Remark
Over discharge detection
2.9V
Over discharge releasing
3.1V
Over charge releasing
4.08-4.13V
Over charge testing voltage
4.15V-4.24V
4) Charging Testing
Name
Testing Specification
Testing Parameters
Testing Condition
Remark
Battery
Chargin
g
Full charge voltage
4.15V
~
4.24V
Charging current
2400mA±200MA
3.7V
Turning light current
<
150mA
Full charge indication
LED long bright
Charging state
Four LED indicator
,
Corresponding battery charging
flashing
Blue LED
5
)
Discharge Testing Parameters
Name
Testing Specification
Testing Parameters
Testing Condition
Remark
Battery
single
discharg
e
Output voltage
5.0V±0.25V
Electronic load
ripple wave
<150mVp-p
oscilloscope
output load voltage
5.0V±0.25V
Electronic load
Inputp load current
2000mA±200mA
Electronic load
Over current
3.3A-4.2A
Discharge rate
>80
%
PCB Conversion
efficiency
short circuit protection
Current more than 5A
150-200US
Discharge instructions
the current voltage in long bright
Instruction