Summary of Contents for C-9602LW

Page 1: ...HTTP WWW HOMBI RU HTTP GSTRU RU E MAIL hombi hombi ru ...

Page 2: ...RU CONTENTS I Description 1 II Specification 1 III Structure 2 IV Mounting and Wiring 3 V Application 6 VI Troubleshooting 7 VII Maintenance 8 VIII Cautions 8 IX Warranty Limited 9 HTTP GSTRU RU E MAIL hombi hombi ru ...

Page 3: ...ate 5 0 W 3 Output capacity and control mode Voltage contact For 12VDC one way pulse solenoid whose driving capability is 1000µF capacitance discharge Volt free contact Volt free normally open contact its capacity is 220V 1A used for controlling connected devices 4 Alarm Density Natural Gas 3000 10 6 6 LEL Liquefied Petroleum Gas 2000 10 6 10 LEL Coal Gas 400 10 6 1 LEL 5 Indicator Power LED Green...

Page 4: ...EDs will flash in turn and the buzzer will sound three times 8 Life of Sensor 5 years 9 Operating Environment Temperature 10 50 Relative Humidity 95 non condensing 10 Dimension 121mm 87mm 47mm 11 Ingress Protection Rating IP30 12 Material and Color of Enclosure ABS ivory white 13 Weight 320g 14 Mounting Hole Distance 15mm III Structure Appearance of the detector is shown in Fig 1 HTTP GSTRU RU E M...

Page 5: ...on where the gas stove is There are still some principles to follow The detector and the gas stove should be placed in the same room The detector detecting natural gas or coal gas should be mounted above 50cm from the resources or the gas stove Natural gas or coal gas is light so it is gathered overhead in the room The detector detecting liquefied HTTP GSTRU RU E MAIL hombi hombi ru ...

Page 6: ...detector and avoid any possible fault please do not mount the detector at following locations a Where affected by exhaust steam or oil smoke from the stove b Where near strong airflow such as 1 5m L 4m Kitchen Ventilator Gas Stove cm Detector detecting liquefied petroleum gas Floor Ceiling Within 30cm Detector detecting natural gas or coal gas HTTP GSTRU RU E MAIL hombi hombi ru ...

Page 7: ...e the detector is partitioned with the gas devices 2 Terminals are shown in Fig 3 Fig 3 K1 K2 Volt free normally open contact it is closed when alarming V V Connects with pipe solenoid or mechanical hand When alarming for 3s 7s there is a forward 12V pulse voltage between V and V 3 Mounting Mounting of C 9602LW is shown in Fig 4 a Fix the bracket on the wall b Align the groove in back of the detec...

Page 8: ...g power supply to the detector after wiring and checking the green LED flashes 3 6 minutes for warm up and then it will light constantly for normal monitoring 2 Alarming When the monitored gas density is over its preset value the detector gives quick intermittent Tick sound with red LED quick flashing and K1 and K2 are closed Bracket H ook G roove HTTP GSTRU RU E MAIL hombi hombi ru ...

Page 9: ...pen manually 3 Fire Alarm Treatment When the detector alarms please immediately open the windows for ventilation Put out any fire do not make new fires Avoid switching on or off any electric appliance find out the reason of leaking and call professional engineers VI Troubleshooting No Fault Reason Solution 1 Alarms after power up Hasn t been powered for a long time or first time powered up It will...

Page 10: ... on its label 2 Don t install the detector at locations with high temperature near stoves or too much oil smoke near kitchen ventilator Keep environment around the detector clean 3 The detector can only control JJ or FCR series solenoid coming with the detector If other models are to be used please consult us 4 The detector should be tested every half year 5 Coal gas detector mustn t test by a lig...

Page 11: ... work after more than 5 hours with power on IX Warranty Limited GST warrants that the product will be free from defects in design materials and workmanship during the warranty period This warranty shall not apply to any product that is found to have been improperly installed or used in any way not in accordance with the instructions supplied with the product Anybody including the agents distributo...

Page 12: ...ST UK Global System Technology PLC Lion Court Staunton Harold Hall Melbourne Road Ashby de la Zouch Leicestershire England LE65 1RT Tel 44 1283 225 478 Fax 44 1283 220 690 Email info gst uk com www gst uk com GST Dubai Global System Technology PLC PO Box 17998 Unit ZA04 JEBEL ALI Free Zone Dubai UAE Tel 971 0 4 8833050 Fax 971 0 4 8833053 Email info gst uk com www gst uk com HTTP GSTRU RU E MAIL h...