Assembly Instruction
SDA 521
SDA 921
SDA 1321
SDA 1721
Page 1: ...Assembly Instruction SDA 521 SDA 921 SDA 1321 SDA 1721 ...
Page 2: ...s equal as possible Beware of short circuits No liability is accepted for any damage caused by faulty connections or inappropriate handling Observe the relevant standards regulations and guidelines on the installa tion and operation of antenna systems The standards IEC EN DINEN61319 1 IEC EN DINENEN 62368 1 and IEC EN DINEN60728 11 must be observed 2 Technical description Application Using the amp...
Page 3: ... PE in accordance with IEC EN DINEN60728 11 Connect the PE connection terminal to a PE rail supplied by customer using the PE wire Cu 4 mm2 9 mm2 DC input Via the DC input a 18V voltage is fed in Attenuation controls Via these controllers the output level of each line can be adjusted attenuation of 0 20dB Terrestrial slope correction Via this controller the slope of the spectrum of the terrestrial...
Page 4: ...eturn loss SAT inputs 10 dB SAT outputs 10 dB TERR input 10 dB TERR output 10 dB Output level SAT IMD3 35 dB 110 dBµV TER IMD3 60 dB 105 dBµV Impedance 75 Ω Dimensions mm 174x125x50 262x125x50 350x125x50 438x125x50 Weight g 1000 1100 1300 Order no G BB 10 05 10 09 10 13 10 17 GSS Grundig Systems GmbH Beuthener Straße 43 D 90471 Nuremberg Phone 49 0 911 633 240 0 Fax 49 0 911 633 240 98 www gss de ...