- 25 -
PHDQ 8008 TSR
input signal therefore must be built in such a way so that the output
symbol rate set ("Number 1") is not exceeded.
The symbol rates of the transport streams built by the cassette can be
measured at the setting "
OUTROUTE ASI=>ASI
" and be displayed in the
respective channel strip.
•
Use the
buttons to place the cursor under the number to be changed
("Number 1") and set the symbol rate with the buttons
.
The value set corresponds to the new output symbol rate.
Increasing the value of "Number 1".
—> The "Number 1" can be increased to any value up to 7500.
Reducing the value of "Number 1".
—> If the value of "Number 2" is very low compared with "Number 1"
, the
"Number 1" can be decreased. To do this, observe the "Number 2" for ap
-
prox. 30 seconds and note the highest value. Add roughly 10 % to this val
-
ue. Do not decrease the "Number 1" lower than the value of "Number 2".
Is the "Number 1" lower than "Number 2" question marks "
??
" appear
in the display. In this case transmission problems may occur.
Bx 4A
6200
(6325) ??
STUFFING
• Press the
button.
—> The "Setting a substitute signal in the case of an incorrect input signal" –
"
FAILURE
" menu is activated.